ArticleOphthalmology. Glaucoma
Local Macular Thickness Relationships between 2 OCT Devices.
Article in Ophthalmology. Glaucoma. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Comparison of the diagnostic performance of two spectral-domain OCT machines in detecting glaucoma in high and non-high axial myopia eyes.International ophthalmology · 2025Article
- Reproducibility of Portable OCT and Comparison with Conventional OCT.Diagnostics (Basel, Switzerland) · 2024Article
- Risk factors for microcystic macular oedema in glaucoma.The British journal of ophthalmology · 2023Observational
- Effect of Testing Frequency on the Time to Detect Glaucoma Progression With Optical Coherence Tomography (OCT) and OCT Angiography.American journal of ophthalmology · 2023Observational
- Detection of Longitudinal Ganglion Cell/Inner Plexiform Layer Change: Comparison of Two Spectral-Domain Optical Coherence Tomography Devices.American journal of ophthalmology · 2021Article
- Macular Optical Coherence Tomography Imaging in Glaucoma.Journal of ophthalmic & vision researchArticle
- Comparison of Ganglion Cell Layer and Ganglion Cell/Inner Plexiform Layer Measures for Detection of Early Glaucoma.Ophthalmology. GlaucomaArticle
- Evaluation of Structural Retinal Layer Alterations in Retinitis Pigmentosa.Romanian journal of ophthalmologyArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
Abstract
purposeTo compare local ganglion cell-inner plexiform layer (GCIPL) thickness measurements between 2 OCT devices and to explore factors that may influence the difference in measurements.
designCross-sectional study.
participantsSixty-nine glaucoma eyes (63 patients) with evidence of central damage or mean deviation (MD) of -6.0 dB or worse on a 24-2 visual field (VF).
methodsCirrus and Spectralis OCT macular volume scans were exported, data from the central 20° of both OCT devices were centered and aligned, and 50 × 50 arrays of 0.4° × 0.4° superpixels were created. We estimated nonparametric (Spearman's) correlations and used Bland-Altman plots to compare GCIPL thickness measurements between the two OCTs at the superpixel level. Factors that may have influenced the differences between thickness measurements between the two devices were explored with linear mixed models.
main outcome measuresPooled and individual-eye Spearman's correlation and agreement between thickness measurements from the two devices.
resultsThe median 24-2 VF MD was -6.8 dB (interquartile range [IQR], -4.9 to -12.3 dB). The overall pooled Spearman's correlation between the two devices for all superpixels and eyes was 0.97 (P < 0.001). The median within-eye correlation coefficient was 0.72 (IQR, 0.59-0.79). Bland-Altman plots demonstrated a systematic bias in most individual eyes, with Spectralis GCIPL measurements becoming larger than Cirrus measurements with increasing superpixel thickness. The average superpixel thickness and distance to the fovea influenced the thickness difference between the two devices in multivariate models (P < 0.001).
conclusionsLocal macular thickness measurements from the Spectralis and Cirrus devices are highly correlated, but not interchangeable. Differences in thickness measurements between the two devices are influenced by the location of superpixels and their thickness.