The Impact of Placement Errors on the Tumor Coverage in MRI-Guided Focal Cryoablation of Prostate Cancer.

Pedro Moreira, Kemal Tuncali, Clare M Tempany, Junichi Tokuda

Abstract read
In one paragraph

Article in Academic radiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Pedro MoreiraDepartment of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis St. Boston, 02115 Massachusetts, USA. Electronic address: plopesdafrotamoreira@bwh.harvard.edu.
Kemal TuncaliDepartment of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis St. Boston, 02115 Massachusetts, USA.
Clare M TempanyDepartment of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis St. Boston, 02115 Massachusetts, USA.
Junichi TokudaDepartment of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis St. Boston, 02115 Massachusetts, USA.

Funding

Image Guided Therapy Center - Ultrasound-based sensor system for the monitoring of COVID-19 patientsP41EB015898 · NIBIB · BRIGHAM AND WOMEN'S HOSPITAL · PI TEMPANY, CLARE M · 2012 to 2021
$18.9M
TRD 3 - Enabling Technologies for Intraprocedural GuidanceP41EB028741 · NIBIB · BRIGHAM AND WOMEN'S HOSPITAL · PI Carl-Fredrik Westin · 2021 to 2026
$10.7M
Open Software Platform for Data-Driven Image-Guided Robotic InterventionsR01EB020667 · NIBIB · BRIGHAM AND WOMEN'S HOSPITAL · PI DIAZ-MERCADO, YANCY, KRIEGER, AXEL · 2015 to 2024
$4.1M
Adaptive Percutaneous Prostate Interventions using Sensorized NeedleR01CA235134 · NCI · BRIGHAM AND WOMEN'S HOSPITAL · PI Nobuhiko Hata, IULIAN IOAN IORDACHITA · 2019 to 2026
$3.6M
Physician Assistance Technology in Image-guided Robotic Intervention of ProstateR01EB030539 · NIBIB · BRIGHAM AND WOMEN'S HOSPITAL · PI HATA, NOBUHIKO, ZHANG, HAICHONG · 2021 to 2024
$2.7M
NCI NIH HHS R01 CA235134NIBIB NIH HHS P41 EB015898NIBIB NIH HHS P41 EB028741NIBIB NIH HHS R01 EB020667NIBIB NIH HHS R01 EB030539
6 · The paper itself

Abstract

RATIONALE AND

objectivesThere have been multiple investigations defining and reporting the effectiveness of focal cryoablation as a treatment option for organ-confined prostate cancer. However, the impact of cryo-needle/probe placement accuracy within the tumor and gland has not been extensively studied. We analyzed how variations in the placement of the cryo-needles, specifically errors leading to incomplete ablation, may affect prostate cancer's resulting cryoablation. MATERIALS AND

methodsWe performed a study based on isothermal models using Monte Carlo simulations to analyze the impact of needle placement errors on tumor coverage and the probability of positive ablation margin. We modeled the placement error as a Gaussian noise on the cryo-needle position. The analysis used retrospective MRI data of 15 patients with biopsy-proven, unifocal, and MRI visible prostate cancer to calculate the impact of placement error on the volume of the tumor encompassed by the -40°C and -20°C isotherms using one to four cryo-needles.

resultsWhen the standard deviation of the placement error reached 3 mm, the tumor coverage was still above 97% with the -20°C isotherm, and above 81% with the -40°C isotherm using two cryo-needles or more. The probability of positive margin was significantly lower considering the -20°C isotherm (0.04 for three needles) than using the -40°C isotherm (0.66 for three needles).

conclusionThe results indicated that accurate cryo-needle placement is essential for the success of focal cryoablation of prostate cancer. The analysis shows that an admissible targeting error depends on the lethal temperature considered and the number of cryo-needles used.

Indexed as

CryosurgeryProstatic NeoplasmsHumansMagnetic Resonance ImagingMaleNeedlesRetrospective StudiesFocal CryoablationMRI-guided CryoablationNeedle placement accuracyProstate Cancer

Identifiers

PMID32863151
PMCPMC7910318

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.