Observational studyJournal of clinical monitoring and computing2021
Accuracy of noninvasive blood pressure measured at the ankle during cesarean delivery under spinal anesthesia.
Observational study in Journal of clinical monitoring and computing, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04199156 (Evaluation of the Non-invasive Blood Pressure Measured at the Ankle During Cesarean Delivery Compared to the Arm), which is not on this map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Evaluation of the Non-invasive Blood Pressure Measured at the Ankle During Cesarean Delivery Compared to the Arm: a Prospective Observational Study
Who cites it
1 citing paper in PubMed, 3 citations in OpenAlex.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In this study, we evaluated the accuracy of oscillometric noninvasive blood pressure (NIBP) measured at the ankle in detecting low arm NIBP during cesarean delivery under spinal anesthesia. In this prospective observational study, a cohort of full-term mothers undergoing elective cesarean delivery under spinal anesthesia was examined. Simultaneous NIBP measurements were obtained from the arm and the ankle. The primary outcome was the accuracy of the ankle NIBP in detecting arm systolic blood pressure (SBP) < 90 mmHg. Other outcomes included the accuracy of ankle NIBP in detecting SBP < 80% of the baseline value. The area under the receiver operating characteristic curve (AUC) was calculated to evaluate the accuracy of ankle NIBP in detecting low arm NIBP. The Bland-Altman analysis was conducted to evaluate the agreement between values. We analyzed 1729 pairs of readings obtained from 97 mothers. Ankle SBP showed good accuracy in detecting SBP < 90 mmHg, with an AUC (95% confidence interval [CI]) of 0.90 (0.89-0.91) and a negative predictive value (NPV) of 99 (98-99%) at a cutoff value of ≤ 103 mmHg. Furthermore, ankle SBP showed good accuracy in detecting SBP < 80% of the baseline value, with an AUC (95% CI) of 0.84 (0.82-0.89) and an NPV of 95 (93-96%) at a cutoff value of ≤ 76% of the ankle baseline SBP. The mean bias between the two sites of measurement was - 5.4 ± 15.5, - 2.0 ± 11, and 0.5 ± 12.1 mmHg for SBP, diastolic blood pressure, and mean arterial pressure, respectively. In conclusion, ankle NIBP measurement is not interchangeable with arm NIBP measurement. However, ankle NIBP measurement showed good accuracy for ruling out low arm NIBP during a cesarean delivery.Clinical trial rejistration: NCT04199156.