Evidence map›Paper›PMID 32860357›Full record

ArticleJournal of biomedical optics2020

Laparoscopic system for simultaneous high-resolution video and rapid hyperspectral imaging in the visible and near-infrared spectral range.

Hannes Köhler, Axel Kulcke, Marianne Maktabi, Yusef Moulla, Boris Jansen-Winkeln, Manuel Barberio, Michele Diana, Ines Gockel, Thomas Neumuth, Claire Chalopin

Open access · goldAbstract read
In one paragraph

Article in Journal of biomedical optics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 33 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
33citing papers in PubMed, 1 pooled it
4.3field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

33 citing papers in PubMed, 1 synthesis or guideline pooled it, 60 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
  13. Article
  14. Article
  15. A High-Speed Hyperspectral Laparoscopic Imaging System.Proceedings of SPIE--the International Society for Optical Engineering · 2023
    Article
  16. Article
  17. Article
  18. Review
  19. Article
  20. Hyperspectral Evaluation of the Human Liver During Major Resection.Annals of surgery open : perspectives of surgical history, education, and clinical approaches · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 3 institutions in 2 countries.

Hannes KöhlerUniversity of Leipzig, Innovation Center Computer Assisted Surgery, Leipzig, Germany.
Axel KulckeDiaspective Vision GmbH, Am Salzhaff, Germany.
Marianne MaktabiUniversity of Leipzig, Innovation Center Computer Assisted Surgery, Leipzig, Germany.
Yusef MoullaUniversity Hospital of Leipzig, Department of Visceral, Thoracic, Transplant, and Vascular Surgery,, Germany.
Boris Jansen-WinkelnUniversity Hospital of Leipzig, Department of Visceral, Thoracic, Transplant, and Vascular Surgery,, Germany.
Manuel BarberioIHU-Strasbourg Institute of Image-Guided Surgery, Strasbourg, France.
Michele DianaIHU-Strasbourg Institute of Image-Guided Surgery, Strasbourg, France.
Ines GockelUniversity Hospital of Leipzig, Department of Visceral, Thoracic, Transplant, and Vascular Surgery,, Germany.
Thomas NeumuthUniversity of Leipzig, Innovation Center Computer Assisted Surgery, Leipzig, Germany.
Claire ChalopinUniversity of Leipzig, Innovation Center Computer Assisted Surgery, Leipzig, Germany.
Leipzig University · DEUniversity Hospital Leipzig · DEInstitut de Chirurgie Guidée par l'Image · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

significanceHyperspectral imaging (HSI) can support intraoperative perfusion assessment, the identification of tissue structures, and the detection of cancerous lesions. The practical use of HSI for minimal-invasive surgery is currently limited, for example, due to long acquisition times, missing video, or large set-ups.

aimAn HSI laparoscope is described and evaluated to address the requirements for clinical use and high-resolution spectral imaging. APPROACH: Reflectance measurements with reference objects and resected human tissue from 500 to 1000 nm are performed to show the consistency with an approved medical HSI device for open surgery. Varying object distances are investigated, and the signal-to-noise ratio (SNR) is determined for different light sources.

resultsThe handheld design enables real-time processing and visualization of HSI data during acquisition within 4.6 s. A color video is provided simultaneously and can be augmented with spectral information from push-broom imaging. The reflectance data from the HSI system for open surgery at 50 cm and the HSI laparoscope are consistent for object distances up to 10 cm. A standard rigid laparoscope in combination with a customized LED light source resulted in a mean SNR of 30 to 43 dB (500 to 950 nm).

conclusionsCompact and rapid HSI with a high spatial- and spectral-resolution is feasible in clinical practice. Our work may support future studies on minimally invasive HSI to reduce intra- and postoperative complications.

Indexed as

Hyperspectral ImagingLaparoscopyDiagnostic ImagingHumansPostoperative Complicationscolor videohyperspectral imaginglaparoscopyminimally invasivevisible and near-infrared

Identifiers

PMID32860357
PMCPMC7453262
OpenAlexW3081787612

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.