Evidence map›Paper›PMID 32856181›Full record

ArticleArchives of orthopaedic and trauma surgery2021

More than a reposition tool: additional wire cerclage leads to increased load to failure in plate osteosynthesis for supracondylar femoral shaft fractures.

Christopher Bliemel, Dan Anrich, Tom Knauf, Ludwig Oberkircher, Daphne Eschbach, Antonio Klasan, Florian Debus, Steffen Ruchholtz, Martin Bäumlein

Open access · hybridAbstract read
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
0.7field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Biomechanical evaluation of cerclage wiring in plated tibia fractures using human and synthetic specimens.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2025
    Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Christopher BliemelCenter for Orthopaedics and Trauma Surgery, University Hospital Giessen-Marburg, Baldingerstrasse, 35043, Marburg, Germany. bliemel@med.uni-marburg.de.ORCID http://orcid.org/0000-0003-4666-3187
Dan AnrichCenter for Orthopaedics and Trauma Surgery, University Hospital Giessen-Marburg, Baldingerstrasse, 35043, Marburg, Germany.
Tom KnaufCenter for Orthopaedics and Trauma Surgery, University Hospital Giessen-Marburg, Baldingerstrasse, 35043, Marburg, Germany.
Ludwig OberkircherCenter for Orthopaedics and Trauma Surgery, University Hospital Giessen-Marburg, Baldingerstrasse, 35043, Marburg, Germany.
Daphne EschbachCenter for Orthopaedics and Trauma Surgery, University Hospital Giessen-Marburg, Baldingerstrasse, 35043, Marburg, Germany.
Antonio KlasanCenter for Orthopaedics and Trauma Surgery, University Hospital Giessen-Marburg, Baldingerstrasse, 35043, Marburg, Germany.
Florian DebusCenter for Orthopaedics and Trauma Surgery, University Hospital Giessen-Marburg, Baldingerstrasse, 35043, Marburg, Germany.
Steffen RuchholtzCenter for Orthopaedics and Trauma Surgery, University Hospital Giessen-Marburg, Baldingerstrasse, 35043, Marburg, Germany.
Martin BäumleinCenter for Orthopaedics and Trauma Surgery, University Hospital Giessen-Marburg, Baldingerstrasse, 35043, Marburg, Germany.
Universitätsklinikum Gießen und Marburg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionSurgical treatment of supracondylar femoral fractures can be challenging. An additional wire cerclage is a suggested way to facilitate fracture reduction prior to plate osteosynthesis. Denudation to the periosteum remains a problematic disadvantage of this procedure. This study analyzed the effect of an additional wire cerclage on the load to failure in plate osteosynthesis of oblique supracondylar femoral shaft fractures. MATERIALS AND

methodsOn eight pairs of non-osteoporotic human femora (mean age 74 years; range 57-95 years), an unstable AO/OTA 32-A2.3 fracture was established. All specimens were treated with a polyaxially locking plate. One femur of each pair was randomly selected to receive an additional fracture fixation with a wire cerclage. A servohydraulic testing machine was used to perform an incremental cyclic axial load with a load to the failure mode.

resultsSpecimens stabilized with solely plate osteosynthesis failed at a mean load of 2450 N (95% CI: 1996-2904 N). In the group with an additional wire cerclage, load to failure was at a mean of 3100 N (95% CI: 2662-3538 N) (p = 0.018). Compression deformation with shearing of the condyle region through cutting of screws out of the condylar bone was the most common reason for failure in both groups of specimens. Whereas axial stiffness was comparable between both groups (p = 0.208), plastic deformation of the osteosynthesis constructs differed significantly (p = 0.035).

conclusionsAn additional wire cerclage significantly increased the load to failure. Therefore, an additional cerclage represents more than just a repositioning aid. With appropriate fracture morphology, a cerclage can significantly improve the strength of the osteosynthesis.

Indexed as

Fracture Fixation, InternalAgedAged, 80 and overBone PlatesBone WiresFemoral FracturesHumansMiddle AgedTreatment FailureBiomechanical analysisLoad to failurePolyaxial angular stable plate osteosynthesisSupracondylar femoral fractureWire cerclage

Identifiers

PMID32856181
PMCPMC8215035
OpenAlexW3082233967

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.