Evidence map›Paper›PMID 32854264›Full record

ArticleMicromachines2020

A Remote-Controlled Robotic System with Safety Protection Strategy Based on Force-Sensing and Bending Feedback for Transcatheter Arterial Chemoembolization.

Junqiang Zhou, Ziyang Mei, Jia Miao, Jingsong Mao, Lingyun Wang, Dezhi Wu, Daoheng Sun, Yang Zhao

Open access · goldAbstract read
In one paragraph

Article in Micromachines, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.8field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 28 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Remote vascular interventional surgery robotics: a literature review.Quantitative imaging in medicine and surgery · 2022
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Junqiang ZhouDepartment of Mechanical and Electrical Engineering, Xiamen University, Xiamen 361102, China.
Ziyang MeiDepartment of Mechanical and Electrical Engineering, Xiamen University, Xiamen 361102, China.
Jia MiaoDepartment of Mechanical and Electrical Engineering, Xiamen University, Xiamen 361102, China.
Jingsong MaoDepartment of Radiology, Xiang'an Hospital of Xiamen University, Xiamen 361102, China.
Lingyun WangDepartment of Mechanical and Electrical Engineering, Xiamen University, Xiamen 361102, China.
Dezhi WuDepartment of Mechanical and Electrical Engineering, Xiamen University, Xiamen 361102, China.ORCID 0000-0001-7152-3069
Daoheng SunDepartment of Mechanical and Electrical Engineering, Xiamen University, Xiamen 361102, China.
Yang ZhaoDepartment of Mechanical and Electrical Engineering, Xiamen University, Xiamen 361102, China.ORCID 0000-0002-6386-2586
Xiamen University · CN

Funding

Fundamental Research Funds for the Central Universities 20720190144Health and Education joint Tackling Plan of Fujian Province WKJ2016-2-21National Natural Science Foundation of China 51505401Science and Technology Program of Shenzhen City JCYJ20180306172700388
6 · The paper itself

Abstract

Transcatheter arterial chemoembolization (TACE) is the common choice of non-open surgery for hepatocellular carcinoma (HCC) now. In this study, a simple TACE robotic system of 4-degree-of-freedom is proposed to get higher accuracy and stability of the surgery operation and reduce X-ray exposure time of the surgeons. The master-slave control strategy is adopted in the robotic system and a customized sigmoid function is designed to optimize the joystick control of the master-slave robotic control system. A force-sensing module is developed to sense the resistance of the guide wire in linear delivery motion and an auxiliary bending feedback method based on constraint pipe with a film sensor is proposed. With two force-sensing methods, the safety strategy of robotic motion with 9 different motion constraint coefficients is given and a human-computer interface is developed. The TACE robot would monitor the value of the force sensor and the analog voltage of the film sensor to adopt the corresponding motion constraint coefficient in every 10 ms. Vascular model experiments were performed to validate the robotic system, and the results showed that the safety strategy could improve the reliability of the operation with immediate speed constraint and avoid potential aggressive delivery.

Indexed as

bending feedbackforce-sensinginterventional robotmaster–slave robotic systemmotion constraint framework

Identifiers

PMID32854264
PMCPMC7569875
OpenAlexW3080656239

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked