In one paragraph

Article in Frontiers in physiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
2.5field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 31 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Review
  11. Article
  12. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Monoem HaddadPhysical Education Department, College of Education, Qatar University, Doha, Qatar.
Souhail HermassiSport Science Program, College of Arts and Sciences, Qatar University, Doha, Qatar.
Zlatan AganovicSport Science Program, College of Arts and Sciences, Qatar University, Doha, Qatar.
Feriel DalansiSport Science Program, College of Arts and Sciences, Qatar University, Doha, Qatar.
Mariam KharbachSport Science Program, College of Arts and Sciences, Qatar University, Doha, Qatar.
Azam Omar MohamedSport Science Program, College of Arts and Sciences, Qatar University, Doha, Qatar.
Khalid W BibiPhysical Education Department, College of Education, Qatar University, Doha, Qatar.
Qatar University · QA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The aim of the study was to assess the validity and reliability of wearable body metric Hexoskin "smart shirt" in measuring heart rate (HR) at pre-exercise and during peak effort in a field test incorporating vigorous movements of the upper body. Measurements were recorded simultaneously using the Hexoskin and Polar Team Pro. Nine male professional handball players (age: 21.8 ± 2.4 years; weight: 83 ± 10.26 kg; height: 1.81 ± 0.09 m; and BMI: 25.17 ± 2.23) volitionally participated in the study by completing two 400 m shuttle run test trials (10 shuttles), each separated by a 48 to 72 h recovery period. Results indicated significant correlations between Hexoskin and Polar Team Pro system in pre-exercise HR. Hexoskin provided erroneous measurements in four of the nine athletes during peak effort. Subsequent correction yielded no consistency between the Polar Team Pro system and Hexoskin between the first and the second trial. Hexoskin showed significant reliability in pre-exercise HR. However, Hexoskin picked up excessive artifact during vigorous physical activity in four of the nine athletes rendering the results in these cases useless. Nevertheless, in athletes where artifact was not an issue, ICC yielded a good estimate. The main findings indicate that Hexoskin has good validity and reliability in measuring pre-exercise HR in handball players and hence may be used with high confidence in slow motion activities. However, vigorous physical activity with jarring multidirectional upper body movements posed a challenge for Hexoskin.

Indexed as

field testmonitoring heart ratePolar Team Provaliditywearable telemetry body metrics shirt

Identifiers

PMID32848879
PMCPMC7413063
OpenAlexW3046306971

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.