Trial reportBMC anesthesiology2020
The effects of labor on airway outcomes with Supreme™ laryngeal mask in women undergoing cesarean delivery under general anesthesia: a cohort study.
Trial report in BMC anesthesiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT02026882 (Supreme Laryngeal Mask Use in Urgent Caesarean Section), which is not on this map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Supreme Laryngeal Mask Use in Urgent Caesarean Section
Who cites it
1 citing paper in PubMed, 3 citations in OpenAlex.
- Anaesthesia for the parturient with multiple gestations.BJA education · 2022Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 5 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundPregnancy is associated with higher incidence of failed endotracheal intubation and is exacerbated by labor. However, the influence of labor on airway outcomes with laryngeal mask airway (LMA) for cesarean delivery is unknown.
methodsThis is a secondary analysis of a prospective cohort study on LMA use during cesarean delivery. Healthy parturients who fasted > 4 h undergoing Category 2 or 3 cesarean delivery with Supreme™ LMA (sLMA) under general anesthesia were included. We excluded parturients with BMI > 35 kg/m
resultsData from 584 parturients were analyzed, with 37.8% in labor. Labor did not significantly affect time to effective ventilation (mean (SD) for labor: 16.0 (5.75) seconds; no labor: 15.3 (3.35); mean difference: -0.65 (95%CI: - 1.49 to 0.18); p = 0.1262). However, labor was associated with increased first-attempt insertion failure and blood on sLMA surface. No reduction in oxygen saturation or pulmonary aspiration was noted.
conclusionsAlthough no significant increase in time to effective ventilation was noted, labor may increase the number of insertion attempts and oropharyngeal trauma with sLMA use for cesarean delivery in parturients at low risk of difficult airway. Future studies should investigate the effects of labor on LMA use in high risk parturients.
trial registrationThe study was prospectively registered at clinicaltrials.gov ( NCT02026882 ) on 3 January 2014.