Evidence map›Paper›PMID 32847548›Full record

Trial reportBMC anesthesiology2020

The effects of labor on airway outcomes with Supreme™ laryngeal mask in women undergoing cesarean delivery under general anesthesia: a cohort study.

Ming Jian Lim, Hon Sen Tan, Chin Wen Tan, Shi Yang Li, Wei Yu Yao, Yong Jing Yuan, Rehena Sultana, Ban Leong Sng

Registry-linked trialOpen access · goldAbstract readClinical Trial
In one paragraph

Trial report in BMC anesthesiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT02026882 (Supreme Laryngeal Mask Use in Urgent Caesarean Section), which is not on this map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT02026882 nacompletednot on this map

Supreme Laryngeal Mask Use in Urgent Caesarean Section

TypeinterventionalSponsorQuanZhou Women and Children's HospitalRan2013 to 2015Enrolled584ConditionsAirway MorbidityArmsSupreme Laryngeal Mask Airway
3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 5 institutions in 2 countries.

Ming Jian LimDepartment of Women's Anesthesia, KK Women's and Children's Hospital, 100 Bukit Timah Road, Singapore, 229899, Singapore.
Hon Sen TanDepartment of Women's Anesthesia, KK Women's and Children's Hospital, 100 Bukit Timah Road, Singapore, 229899, Singapore.
Chin Wen TanDepartment of Women's Anesthesia, KK Women's and Children's Hospital, 100 Bukit Timah Road, Singapore, 229899, Singapore.
Shi Yang LiDepartment of Anesthesiology and Perioperative Medicine, Quanzhou Macare Women's Hospital, Quanzhou, Fujian Province, China.
Wei Yu YaoDepartment of Anesthesiology and Perioperative Medicine, Quanzhou Macare Women's Hospital, Quanzhou, Fujian Province, China.
Yong Jing YuanDepartment of Anesthesiology, Qinghai University Affiliated Hospital, Xining, Qinghai Province, China.
Rehena SultanaCentre for Quantitative Medicine, Duke-NUS Medical School, 8 College Road, Singapore, 169857, Singapore.
Ban Leong SngDepartment of Women's Anesthesia, KK Women's and Children's Hospital, 100 Bukit Timah Road, Singapore, 229899, Singapore. sng.ban.leong@singhealth.com.sg.ORCID 0000-0001-5374-4271
KK Women's and Children's Hospital · SGFujian Women and Children Hospital · CNDuke-NUS Medical School · SGQinghai University Affiliated Hospital · CNSingHealth · SG

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPregnancy is associated with higher incidence of failed endotracheal intubation and is exacerbated by labor. However, the influence of labor on airway outcomes with laryngeal mask airway (LMA) for cesarean delivery is unknown.

methodsThis is a secondary analysis of a prospective cohort study on LMA use during cesarean delivery. Healthy parturients who fasted > 4 h undergoing Category 2 or 3 cesarean delivery with Supreme™ LMA (sLMA) under general anesthesia were included. We excluded parturients with BMI > 35 kg/m

resultsData from 584 parturients were analyzed, with 37.8% in labor. Labor did not significantly affect time to effective ventilation (mean (SD) for labor: 16.0 (5.75) seconds; no labor: 15.3 (3.35); mean difference: -0.65 (95%CI: - 1.49 to 0.18); p = 0.1262). However, labor was associated with increased first-attempt insertion failure and blood on sLMA surface. No reduction in oxygen saturation or pulmonary aspiration was noted.

conclusionsAlthough no significant increase in time to effective ventilation was noted, labor may increase the number of insertion attempts and oropharyngeal trauma with sLMA use for cesarean delivery in parturients at low risk of difficult airway. Future studies should investigate the effects of labor on LMA use in high risk parturients.

trial registrationThe study was prospectively registered at clinicaltrials.gov ( NCT02026882 ) on 3 January 2014.

Indexed as

AdultAirway ManagementAnesthesia, GeneralCesarean SectionCohort StudiesFemaleHumansIntubation, IntratrachealLabor, ObstetricLaryngeal MasksPregnancyProspective StudiesTidal VolumeAirwayMallampati scoreObstetrics

Identifiers

PMID32847548
PMCPMC7449044
OpenAlexW3081151761

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.