Evidence map›Paper›PMID 32845428›Full record

Article3D printing in medicine2020

The effect of metal artefact on the design of custom 3D printed acetabular implants.

Anna Di Laura, Johann Henckel, Robert Wescott, Harry Hothi, Alister J Hart

Open access · goldAbstract read
In one paragraph

Article in 3D printing in medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.8field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Anna Di LauraThe Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, London, HA7 4LP, UK. anna.laura.14@ucl.ac.uk.ORCID http://orcid.org/0000-0002-4212-3741
Johann HenckelThe Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, London, HA7 4LP, UK.
Robert WescottInstitute of Orthopaedics and Musculoskeletal Science, University College London, London, UK.
Harry HothiThe Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, London, HA7 4LP, UK.
Alister J HartThe Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, London, HA7 4LP, UK.
Royal National Orthopaedic Hospital · GBUniversity College London · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background3D Printed custom-made implants constitute a viable option in patients with acetabular Paprosky III defects. In these patients, needing complex hip revision surgery, the appreciation of the bony defect is crucial to assure stable fixation of the customised implant, often intended to replace a failed one. We aimed to understand the effect of metal artefact on the design of customised implants.

methods26 patients with massive acetabular defects were referred, between May 2016 and September 2018, to our institution classified as "un-reconstructable" by other hospitals. They all received custom 3D-printed acetabular cups. A subset of them underwent two-stage revision surgery due to infection. We then extended the two-stage procedure to the cases where metal artefacts were significantly affecting the reading of the CT scans. CT scans of patients' pelvises were taken pre and post-implant removal. We assessed for changes in bony shape and volume of the pelvis using 3D imaging software and quantified the effect on implant design with CAD software.

resultsEight (out of 26) patients (31%) underwent two-stage revision surgery. The CT bony reconstructions between the two timepoints changed in all cases. The changes were mostly associated to the shape and distribution of the acetabular defects. Three of these cases (37.5%) showed a remarkable difference in the remaining bone that led to a change in implant design. So far, there has been no difference in the clinical outcome between the patients who underwent single (n = 18) and two-stage surgery (n = 8).

conclusionsThe shape of the acetabulum reconstructed from CT data is potentially altered by metal artefact and bone excised during removal of the failed component. For "end-of-road" acetabular reconstruction, we recommend surgeons consider the use of two-stage surgery to enable a reliable fitting of the complex shape of 3D-printed implants.

Indexed as

Computed tomographyCustom 3D printed implantsMetal artefactPaprosky acetabular classificationRevision hip surgery

Identifiers

PMID32845428
PMCPMC7450581
OpenAlexW3080616551

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.