Evidence map›Paper›PMID 32845133›Full record

ArticleAnalytical chemistry2020

Dynamic Range Expansion by Gas-Phase Ion Fractionation and Enrichment for Imaging Mass Spectrometry.

Boone M Prentice, Daniel J Ryan, Kerri J Grove, D Shannon Cornett, Richard M Caprioli, Jeffrey M Spraggins

Abstract read
In one paragraph

Article in Analytical chemistry, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Review
  2. Article
  3. Mass Spectrometry Imaging.Analytical chemistry · 2025
    Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Imaging mass spectrometry reveals complex lipid distributions acrossJournal of mass spectrometry and advances in the clinical lab · 2022
    Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Boone M PrenticeDepartment of Biochemistry, Vanderbilt University, Nashville, Tennessee 37232, United States.ORCID 0000-0002-1927-9457
Daniel J RyanExxonMobil Research and Engineering Company, Annandale, New Jersey 08801, United States.ORCID 0000-0001-8201-1472
Kerri J GroveMass Spectrometry Research Center, Vanderbilt University, Nashville, Tennessee 37232, United States.
D Shannon CornettBruker Daltonics, Billerica, Massachusetts 01821, United States.
Richard M CaprioliDepartment of Biochemistry, Vanderbilt University, Nashville, Tennessee 37232, United States.ORCID 0000-0001-5859-3310
Jeffrey M SpragginsDepartment of Biochemistry, Vanderbilt University, Nashville, Tennessee 37232, United States.ORCID 0000-0001-9198-5498

Funding

Training (pp 214-245)P41GM103391 · NIGMS · VANDERBILT UNIVERSITY · PI CAPRIOLI, RICHARD M · 2012 to 2020
$17.7M
NIGMS NIH HHS P41 GM103391
6 · The paper itself

Abstract

In the analysis of biological tissue by imaging mass spectrometry (IMS), the limit of detection and dynamic range are of paramount importance in obtaining experimental results that provide insight into underlying biological processes. Many important biomolecules are present in the tissue milieu in low concentrations and in complex mixtures with other compounds of widely ranging abundances, challenging the limits of analytical technologies. In many IMS experiments, the ion signal can be dominated by a few highly abundant ion species. On trap-based instrument platforms that accumulate ions prior to mass analysis, these high abundance ions can diminish the detection and dynamic range of lower abundance ions. Herein, we describe two strategies for combating these challenges during IMS experiments on a hybrid QhFT-ICR MS. In one iteration, the mass resolving capabilities of a quadrupole mass filter are used to selectively enrich ions of interest via a technique previously termed continuous accumulation of selected ions. Second, we have introduced a supplemental dipolar AC waveform to the quadrupole mass filter of a commercial QhFT-ICR mass spectrometer to perform selected ion ejection prior to the ion accumulation region. This setup allows the selective ejection of the most abundant ion species prior to ion accumulation, thereby greatly improving the molecular depth with which IMS can probe tissue samples. The gain in sensitivity of both of these approaches roughly scales with the number of accumulated laser shots up to the charge capacity of the ion accumulation cell. The efficiencies of these two strategies are described here by performing lipid imaging mass spectrometry analyses of a rat brain.

Indexed as

AnimalsBrainGasesIonsLipidsMass SpectrometryRatsGasesIonsLipids

Identifiers

PMID32845133
PMCPMC8340028

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.