Evidence map›Paper›PMID 32844515›Full record

ArticleJournal of orthopaedic research : official publication of the Orthopaedic Research Society2021

Effect of cyclic loading on the stability of screws placed in the locking plates used to bridge segmental bone defects.

Remigiusz M Grzeskowiak, Laura R Freeman, David P Harper, David E Anderson, Pierre-Yves Mulon

Open access · hybridAbstract read
In one paragraph

Article in Journal of orthopaedic research : official publication of the Orthopaedic Research Society, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
0.9field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Interface stability of intramedullary nail locking configurations under combined axial and torsional loading.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2026
    Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Effect of cyclic loading on the stability of screws placed in the locking plates used to bridge segmental bone defects.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2021
    Article
  8. Article
  9. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Remigiusz M GrzeskowiakLarge Animal Clinical Sciences, University of Tennessee College of Veterinary Medicine, Knoxville, Tennessee, USA.ORCID 0000-0002-8656-5162
Laura R FreemanLarge Animal Clinical Sciences, University of Tennessee College of Veterinary Medicine, Knoxville, Tennessee, USA.
David P HarperThe Center for Renewable Carbon, Institute of Agriculture, University of Tennessee, Knoxville, Tennessee, USA.
David E AndersonLarge Animal Clinical Sciences, University of Tennessee College of Veterinary Medicine, Knoxville, Tennessee, USA.ORCID 0000-0003-0745-7591
Pierre-Yves MulonLarge Animal Clinical Sciences, University of Tennessee College of Veterinary Medicine, Knoxville, Tennessee, USA.ORCID 0000-0001-8722-4370
University of Tennessee at Knoxville · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The objective of this study was to evaluate the ex vivo effect of cyclic loading on the stability of screws placed in locking plates used to bridge segmental bone defects. The primary interface stability was assessed using peak reverse torque. Eighteen, 8-hole stainless-steel 4.5 mm locking plates and 4.0-mm self-tapping locking-head screws were used to stabilize 40-mm segmental defects in goat tibiae. Treatment groups included control constructs without cyclic loading (n = 6) and constructs tested to 5000 (n = 6) and 10,000 cycles (n = 6) of 600 N compressive axial loading. The insertion of all screws was standardized to 400 N-cm insertion torque. Peak reverse torque was measured immediately after screw placement (control), or after the completion of the respective loading cycles. The difference between treatment groups was compared using univariate analysis of variance. The analysis revealed a significant difference in peak reverse torque of the screws among the treatment groups (p = .000). The mean reverse torque values equaled 343.5 ± 18.3 N-cm for non-cycled controls, 303.3 ± 25.9 and 296.0 ± 42.9 N-cm after 5000 and 10,000 cycles, respectively. Among all treatment groups, screws placed in the distal bone segment tended to have lesser peak reverse torque reduction than those placed in the proximal segment and the difference was proportional to the number of cycles (p = .562; p = .255; p = .013 in control, and after 5000 and 10,000 cycles, respectively). Cyclic loading may have a negative effect on the primary stability of screws placed in locking plate constructs used to bridge segmental bone defects and could contribute to the risk of screw loosening.

Indexed as

Bone PlatesBone ScrewsAnimalsCompressive StrengthGoatsMaterials TestingTorqueWeight-Bearingfractureimplant stabilitylocking plateslocking screwsorthopedicspeak reverse torquesegmental defect

Identifiers

PMID32844515
PMCPMC7984344
OpenAlexW3080324735

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.