ArticleJournal of orthopaedic research : official publication of the Orthopaedic Research Society2021
Effect of cyclic loading on the stability of screws placed in the locking plates used to bridge segmental bone defects.
Article in Journal of orthopaedic research : official publication of the Orthopaedic Research Society, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 10 citations in OpenAlex.
- Distal Humerus Fracture in a 28-Year-Old Male with Achondroplasia Treated with Reconstruction Plate: Case Report and Review of Literature.Journal of orthopaedic case reports · 2026Article
- Interface stability of intramedullary nail locking configurations under combined axial and torsional loading.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2026Article
- Fixation Failure in Osteoporotic Bone: A Review of Complications and Outcomes.Indian journal of orthopaedics · 2025Review
- Biomechanical analysis of a novel screw system with a variable locking angle in mandible angle fractures.Medical & biological engineering & computing · 2023Article
- Biomechanical evaluation of interlocking nail and locking compression plating for stabilization of ovine critical-sized segmental tibia defects.Annals of translational medicine · 2023Article
- Xenogenic Implantation of Human Mesenchymal Stromal Cells Using a Novel 3D-Printed Scaffold of PLGA and Graphene Leads to a Significant Increase in Bone Mineralization in a Rat Segmental Femoral Bone Defect.Nanomaterials (Basel, Switzerland) · 2023Article
- Effect of cyclic loading on the stability of screws placed in the locking plates used to bridge segmental bone defects.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2021Article
- Temporal Changes in Reverse Torque of Locking-Head Screws Used in the Locking Plate in Segmental Tibial Defect in Goat Model.Frontiers in surgery · 2021Article
- Bone and Cartilage Interfaces With Orthopedic Implants: A Literature Review.Frontiers in surgery · 2020Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The objective of this study was to evaluate the ex vivo effect of cyclic loading on the stability of screws placed in locking plates used to bridge segmental bone defects. The primary interface stability was assessed using peak reverse torque. Eighteen, 8-hole stainless-steel 4.5 mm locking plates and 4.0-mm self-tapping locking-head screws were used to stabilize 40-mm segmental defects in goat tibiae. Treatment groups included control constructs without cyclic loading (n = 6) and constructs tested to 5000 (n = 6) and 10,000 cycles (n = 6) of 600 N compressive axial loading. The insertion of all screws was standardized to 400 N-cm insertion torque. Peak reverse torque was measured immediately after screw placement (control), or after the completion of the respective loading cycles. The difference between treatment groups was compared using univariate analysis of variance. The analysis revealed a significant difference in peak reverse torque of the screws among the treatment groups (p = .000). The mean reverse torque values equaled 343.5 ± 18.3 N-cm for non-cycled controls, 303.3 ± 25.9 and 296.0 ± 42.9 N-cm after 5000 and 10,000 cycles, respectively. Among all treatment groups, screws placed in the distal bone segment tended to have lesser peak reverse torque reduction than those placed in the proximal segment and the difference was proportional to the number of cycles (p = .562; p = .255; p = .013 in control, and after 5000 and 10,000 cycles, respectively). Cyclic loading may have a negative effect on the primary stability of screws placed in locking plate constructs used to bridge segmental bone defects and could contribute to the risk of screw loosening.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.