Evidence map›Paper›PMID 32841500›Full record

ArticleJournal of applied clinical medical physics2020

Characterization of an inorganic scintillator for small-field dosimetry in MR-guided radiotherapy.

Davide Cusumano, Lorenzo Placidi, Emiliano D'Agostino, Luca Boldrini, Sebastiano Menna, Vincenzo Valentini, Marco De Spirito, Luigi Azario

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
2.3field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Davide CusumanoFondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy.ORCID https://orcid.org/0000-0001-8626-0003
Lorenzo PlacidiFondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy.ORCID https://orcid.org/0000-0003-0058-9145
Emiliano D'AgostinoDoseVue NV, Bioville, Diepenbeek, Belgium.ORCID https://orcid.org/0000-0003-0468-4836
Luca BoldriniFondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy.ORCID https://orcid.org/0000-0002-5631-1575
Sebastiano MennaFondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy.ORCID https://orcid.org/0000-0003-0556-3593
Vincenzo ValentiniFondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy.ORCID https://orcid.org/0000-0003-4637-6487
Marco De SpiritoFondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy.ORCID https://orcid.org/0000-0003-4260-5107
Luigi AzarioFondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy.ORCID https://orcid.org/0000-0001-8575-8627
Agostino Gemelli University Polyclinic · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionAim of this study is to dosimetrically characterize a new inorganic scintillator designed for magnetic resonance-guided radiotherapy (MRgRT) in the presence of 0.35 tesla magnetic field (B).

methodsThe detector was characterized in terms of signal to noise ratio (SNR), reproducibility, dose linearity, angular response, and dependence by energy, field size, and B orientation using a 6 MV magnetic resonance (MR)-Linac and a water tank. Field size dependence was investigated by measuring the output factor (OF) at 1.5 cm. The results were compared with those measured using other detectors (ion chamber and synthetic diamond) and those calculated using a Monte Carlo (MC) algorithm. Energy dependence was investigated by acquiring a percentage depth dose (PDD) curve at two field sizes (3.32 × 3.32 and 9.96 × 9.96 cm

resultsThe mean SNR was 116.3 ± 0.6. Detector repeatability was within 1%, angular dependence was <2% and its response variation based on the orientation with respect to the B lines was <1%. The detector has a temporal resolution of 10 Hz and it showed a linear response (R

conclusionThe inorganic scintillator in the present form can represent a valuable detector for small-field dosimetry and periodic quality controls at MR-Linacs such as dose stability, OFs, and dose linearity. In particular, the detector can be effectively used for small-field dosimetry at 1.5 cm depth and for PDD measurements if the field dimension of 3.32 × 3.32 cm

Indexed as

RadiometryRadiotherapy, Image-GuidedHumansMonte Carlo MethodParticle AcceleratorsReproducibility of Resultsinorganic scintillatorMR-guided radiotherapyreal-time dosimetrysmall-field dosimetry

Identifiers

PMID32841500
PMCPMC7497936
OpenAlexW3080806649

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.