Evidence map›Paper›PMID 32839375›Full record

ArticleDiagnostics (Basel, Switzerland)2020

Preoperative Computer-Assisted Laparoscopy Planning for the Minimally Invasive Surgical Repair of Hiatal Hernia.

Silviu Daniel Preda, Cătălin Ciobîrcă, Gabriel Gruionu, Andreea Șoimu Iacob, Konstantinos Sapalidis, Lucian Gheorghe Gruionu, Ștefan Castravete, Ștefan Pătrașcu, Valeriu Șurlin

Open access · goldAbstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.6field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 2 countries.

Silviu Daniel PredaDepartment of Surgery, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania.ORCID 0000-0002-0232-0070
Cătălin CiobîrcăFaculty of Automation, Computers and Electronics, University of Craiova, 200776 Craiova, Romania.
Gabriel GruionuFaculty of Mechanics, University of Craiova, 200512 Craiova, Romania.
Andreea Șoimu IacobFaculty of Automation, Computers and Electronics, University of Craiova, 200776 Craiova, Romania.
Konstantinos Sapalidis3rd Department of Surgery, "AHEPA" University Hospital, Aristotle University of Thessaloniki, Medical School, 54621 Thessaloniki, Greece.
Lucian Gheorghe GruionuFaculty of Mechanics, University of Craiova, 200512 Craiova, Romania.
Ștefan CastraveteCaelynx Europe Ltd., 200374 Craiova, Romania.
Ștefan PătrașcuDepartment of Surgery, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania.ORCID 0000-0003-4211-1377
Valeriu ȘurlinDepartment of Surgery, University of Medicine and Pharmacy of Craiova, 200349 Craiova, Romania.
University of Craiova · ROUniversity of Medicine and Pharmacy of Craiova · ROAristotle University of Thessaloniki · GR

Funding

European Social Fund POCU 380/6/13/123990
6 · The paper itself

Abstract

Minimal invasive surgical procedures such as laparoscopy are preferred over open surgery due to faster postoperative recovery, less trauma and inflammatory response, and less scarring. Laparoscopic repairs of hiatal hernias require pre-procedure planning to ensure appropriate exposure and positioning of the surgical ports for triangulation, ergonomics, instrument length and operational angles to avoid the fulcrum effect of the long and rigid instruments. We developed a novel surgical planning and navigation software, iMTECH to determine the optimal location of the skin incision and surgical instrument placement depth and angles during laparoscopic surgery. We tested the software on five cases of human hiatal hernia to assess the feasibility of the stereotactic reconstruction of anatomy and surgical planning. A whole-body CT investigation was performed for each patient, and abdominal 3D virtual models were reconstructed from the CT scans. The optical trocar access point was placed on the xipho-umbilical line. The distance on the skin between the insertion point of the optical trocar and the xiphoid process was 159.6, 155.7, 143.1, 158.3, and 149.1 mm, respectively, at a 40° elevation angle. Following the pre-procedure planning, all patients underwent successful surgical laparoscopic procedures. The user feedback was that planning software significantly improved the ergonomics, was easy to use, and particularly useful in obese patients with large hiatal defects where the insertion points could not be placed in the traditional positions. Future studies will assess the benefits of the planning system over the conventional, empirical trocar positioning method in more patients with other surgical challenges.

Indexed as

hiatal hernialaparoscopysurgical planningtraining

Identifiers

PMID32839375
PMCPMC7554699
OpenAlexW3080688665

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.