Evidence map›Paper›PMID 32836390›Full record

ArticleMicrochemical journal : devoted to the application of microtechniques in all branches of science2020

Monitoring the quality of ethanol-based hand sanitizers by low-cost near-infrared spectroscopy.

Celio Pasquini, Maria C Hespanhol, Kaíque A M L Cruz, Alexandre F Pereira

Open access · greenAbstract read
In one paragraph

Article in Microchemical journal : devoted to the application of microtechniques in all branches of science, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
4.5field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 44 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Celio PasquiniInstituto de Química, Universidade estadual de Campinas (UNICAMP), Rua Monteiro Lobato, 290, Campinas, SP 13083-862, Brazil.
Maria C HespanholDepartamento de Química, Universidade Federal de Viçosa (UFV), Campus da UFV, Viçosa, MG 36570-900, Brazil.
Kaíque A M L CruzDepartamento de Química, Universidade Federal de Viçosa (UFV), Campus da UFV, Viçosa, MG 36570-900, Brazil.
Alexandre F PereiraDepartamento de Química, Universidade Federal de Viçosa (UFV), Campus da UFV, Viçosa, MG 36570-900, Brazil.
Universidade Federal de Viçosa · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The use of near-infrared spectroscopy (NIRS) based on a low-cost portable instrument for monitoring the quality of the three major formulations of ethanol-based hand sanitizers used for prevention against CoVID-19 disease is described. The quality of the sanitizers was evaluated using two approaches. In the first, a qualitative method was developed to identify gross non-conformities, using NIR spectral data compression by principal components analysis and projection of the spectrum of the tested sample in the principal component space delimited by samples of sanitizers prepared in the laboratory. In the second, a quantitative method was designed to determine the active substance (ethanol) employing multivariate regression based on partial least squares. The results demonstrate that the first approach can be used to detect non-conformities in the sanitizer composition, mostly associated with incorrect ethanol content. The second explores the use of NIRS for determination of the ethanol content in the three formulations aiming the quality control of the sanitizer manufacturing process. The ethanol content can be determined with an absolute root mean square error of prediction (RMSEP) equal to 0.68% (m/m), 0.83% (m/m) and 1.0% (v/v) for the three formulations evaluated. The RMSEP was estimated as 1.3% (m/m) for the commercial products. The measurement protocol takes approximately 1 min and requires only about 120 µL of a sample. Besides, NIRS was employed to compare the rate of volatilization of the ethanol in the different formulations, an important parameter concerning the efficacy of ethanol-based sanitizers.

Indexed as

Alcohol gel qualityCoVID-19 preventionEthanol-based sanitizersEthanol volatilization rateMultivariate analysisNear-infrared spectroscopy

Identifiers

PMID32836390
PMCPMC7430279
OpenAlexW3049480539

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.