Evidence map›Paper›PMID 32835141›Full record

ArticleHardwareX2020

Partially RepRapable automated open source bag valve mask-based ventilator.

Aliaksei Petsiuk, Nagendra G Tanikella, Samantha Dertinger, Adam Pringle, Shane Oberloier, Joshua M Pearce

Erratum issuedOpen access · goldAbstract read
In one paragraph

Article in HardwareX, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
5.9field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 62 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Differential Pressure Spirometry for Mechanical Ventilation Using Dichotomic Search.IEEE transactions on instrumentation and measurement · 2021
    Article
  15. The role of 3D printing during COVID-19 pandemic: a review.Progress in additive manufacturing · 2021
    Review
  16. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors at 1 institution in 3 countries.

Aliaksei PetsiukDepartment of Electrical & Computer Engineering, Michigan Technological University, USA.
Nagendra G TanikellaDepartment of Materials Science & Engineering, Michigan Technological University, USA.
Samantha DertingerBiomedical Engineering, Michigan Technological University, USA.
Adam PringleDepartment of Materials Science & Engineering, Michigan Technological University, USA.
Shane OberloierDepartment of Electrical & Computer Engineering, Michigan Technological University, USA.
Joshua M PearceDepartment of Electrical & Computer Engineering, Michigan Technological University, USA.
Michigan Technological University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study describes the development of a simple and easy-to-build portable automated bag valve mask (BVM) compression system, which, during acute shortages and supply chain disruptions can serve as a temporary emergency ventilator. The resuscitation system is based on the Arduino controller with a real-time operating system installed on a largely RepRap 3-D printable parametric component-based structure. The cost of the materials for the system is under $170, which makes it affordable for replication by makers around the world. The device provides a controlled breathing mode with tidal volumes from 100 to 800 mL, breathing rates from 5 to 40 breaths/minute, and inspiratory-to-expiratory ratio from 1:1 to 1:4. The system is designed for reliability and scalability of measurement circuits through the use of the serial peripheral interface and has the ability to connect additional hardware due to the object-oriented algorithmic approach. Experimental results after testing on an artificial lung for peak inspiratory pressure (PIP), respiratory rate (RR), positive end-expiratory pressure (PEEP), tidal volume, proximal pressure, and lung pressure demonstrate repeatability and accuracy exceeding human capabilities in BVM-based manual ventilation. Future work is necessary to further develop and test the system to make it acceptable for deployment outside of emergencies such as with COVID-19 pandemic in clinical environments, however, the nature of the design is such that desired features are relatively easy to add using protocols and parametric design files provided.

Indexed as

3-D printingCoronavirusCoronavirus pandemicCOVID-19Embedded systemsInfluenza pandemicMedical hardwareOpen hardwareOpen sourceOpen source medical hardwarePandemicPandemic ventilatorReal-time operating systemRepRapSingle-limbVentilationVentilator

Identifiers

PMID32835141
PMCPMC7417990
OpenAlexW3047967775

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.