ArticleHardwareX2020
Partially RepRapable automated open source bag valve mask-based ventilator.
Article in HardwareX, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 16 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed, 62 citations in OpenAlex.
- Concept and Evolution in 3D Printing for Excellence in Healthcare.Current medicinal chemistry · 2025Review
- COVID-19 Lessons Learned: Response to the Anticipated Ventilator Shortage.Respiratory care · 2023Article
- Article
- Overcoming supply disruptions during pandemics by utilizing found hardware for open source gentle ventilation.HardwareX · 2022Article
- The personal protective equipment fabricated via 3D printing technology during COVID-19.Annals of 3D printed medicine · 2022Article
- The HEV Ventilator: at the interface between particle physics and biomedical engineering.Royal Society open science · 2022Article
- Recent advances in low-cost, portable automated resuscitator systems to fight COVID-19.Health and technology · 2022Review
- Data automated bag breathing unit for COVID-19 ventilator shortages.Intensive care medicine experimental · 2021Article
- Physiologic-range three/two-way valve for respiratory circuits.HardwareX · 2021Article
- Article
- Role of additive manufacturing in medical application COVID-19 scenario: India case study.Journal of manufacturing systems · 2021Article
- VentMon: An open source inline ventilator tester and monitor.HardwareX · 2021Article
- COVENT-Tester: A low-cost, open source ventilator tester.HardwareX · 2021Article
- Differential Pressure Spirometry for Mechanical Ventilation Using Dichotomic Search.IEEE transactions on instrumentation and measurement · 2021Article
- The role of 3D printing during COVID-19 pandemic: a review.Progress in additive manufacturing · 2021Review
- Open source high-temperature RepRap for 3-D printing heat-sterilizable PPE and other applications.HardwareX · 2020Article
Corrections and comments
- Erratum issued
Authors and funding
6 authors at 1 institution in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This study describes the development of a simple and easy-to-build portable automated bag valve mask (BVM) compression system, which, during acute shortages and supply chain disruptions can serve as a temporary emergency ventilator. The resuscitation system is based on the Arduino controller with a real-time operating system installed on a largely RepRap 3-D printable parametric component-based structure. The cost of the materials for the system is under $170, which makes it affordable for replication by makers around the world. The device provides a controlled breathing mode with tidal volumes from 100 to 800 mL, breathing rates from 5 to 40 breaths/minute, and inspiratory-to-expiratory ratio from 1:1 to 1:4. The system is designed for reliability and scalability of measurement circuits through the use of the serial peripheral interface and has the ability to connect additional hardware due to the object-oriented algorithmic approach. Experimental results after testing on an artificial lung for peak inspiratory pressure (PIP), respiratory rate (RR), positive end-expiratory pressure (PEEP), tidal volume, proximal pressure, and lung pressure demonstrate repeatability and accuracy exceeding human capabilities in BVM-based manual ventilation. Future work is necessary to further develop and test the system to make it acceptable for deployment outside of emergencies such as with COVID-19 pandemic in clinical environments, however, the nature of the design is such that desired features are relatively easy to add using protocols and parametric design files provided.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.