ArticleJournal of clinical monitoring and computing2021
Multi-model generalised predictive control for intravenous anaesthesia under inter-individual variability.
Article in Journal of clinical monitoring and computing, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Inter-individual variability possesses a major challenge in the regulation of hypnosis in anesthesia. Understanding the variability towards anesthesia effect is expected to assist the design of controller for anesthesia regulation. However, such studies are still very scarce in the literature. This study aims to analyze the inter-individual variability in propofol pharmacokinetics/pharmacodynamics (PK/PD) model and proposed a suitable controller to tackle the variability. This study employed Sobol' sensitivity analysis to identify significance parameters in propofol PK/PD model that affects the model output Bispectral Index (BIS). Parameters' range is obtained from reported clinical data. Based on the finding, a multi-model generalized predictive controller was proposed to regulate propofol in tackling patient variability. [Formula: see text] (concentration that produces 50% of the maximum effect) was found to have a highly-determining role on the uncertainty of BIS. In addition, the Hill coefficient, [Formula: see text], was found to be significant when there is a drastic input, especially during the induction phase. Both of these parameters only affect the process gain upon model linearization. Therefore, a predictive controller based on switching of model with different process gain is proposed. Simulation result shows that it is able to give a satisfactory performance across a wide population. Both the parameters [Formula: see text] and [Formula: see text], which are unknown before anesthesia procedure, were found to be highly significant in contributing the uncertainty of BIS. Their range of variability must be considered during the design and evaluation of controller. A linear controller may be sufficient to tackle most of the variability since both [Formula: see text] and [Formula: see text] would be translated into process gain upon linearization.
Indexed as
Identifiers
32833146What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.