Observational studyHeart and vessels2021
Usefulness of subcutaneous implantable cardioverter-defibrillator therapy in patients with Brugada syndrome.
Observational study in Heart and vessels, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 6 citations in OpenAlex.
- Unconventional diagnosis of bradyarrhythmic syncope in Brugada syndrome: a case report.European heart journal. Case reports · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 1 institution in 1 country.
Funding
Abstract
Implantable cardioverter-defibrillators (ICDs) are the main therapy to prevent sudden cardiac death in patients with Brugada syndrome (BrS). The subcutaneous ICD (S-ICD) can eliminate lead-associated complications compared with transvenous ICD (TV-ICD). However, S-ICD is susceptible to T-wave oversensing (TWOS) and may result in more frequent inappropriate shocks in patients with BrS. This study aimed to compare inappropriate shocks between TV-ICD and S-ICD in patients with BrS. We enrolled 32 patients with BrS (including one woman; mean age 52 ± 18 years) who were implanted with ICD (23 TV-ICDs and 9 S-ICDs) between January 2002 and November 2018 in Oita University Hospital. We carried out a standard surface electrocardiogram (ECG) screening tests in both supine and standing positions prior to S-ICD implantation. The patients received routine clinical review every month and device monitoring every 4 months. The period of follow-up was 129 ± 51 months. Six patients with BrS and TV-ICDs experienced inappropriate shocks (26%) with their ICD therapy. In contrast, two patients with BrS and S-ICDs experienced inappropriate shocks (22%). There was no significant difference between the two groups (P = 0.82). Although one case in the S-ICD group experienced TWOS-induced inappropriate shock, SMART Pass (new high-pass filter) prevented the subsequent recurrence of inappropriate shocks during ICD therapy. Our results suggest that S-ICD is not inferior to TV-ICD in the incidence of inappropriate shocks. SMART Pass may be a useful tool to prevent inappropriate ICD shocks by TWOS in patients with BrS.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.