Evidence map›Paper›PMID 32829631›Full record

ArticleAnalytical chemistry2020

3D Printed Microfluidic Devices for Solid-Phase Extraction and On-Chip Fluorescent Labeling of Preterm Birth Risk Biomarkers.

Anna V Bickham, Chao Pang, Benjamin Q George, David J Topham, Jacob B Nielsen, Gregory P Nordin, Adam T Woolley

Open access · greenAbstract read
In one paragraph

Article in Analytical chemistry, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
3.0field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 39 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
  14. Review
  15. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Anna V BickhamDepartment of Chemistry and Biochemistry, Brigham Young University, Provo, Utah 84602 United States.
Chao PangDepartment of Chemistry and Biochemistry, Brigham Young University, Provo, Utah 84602 United States.
Benjamin Q GeorgeDepartment of Chemistry and Biochemistry, Brigham Young University, Provo, Utah 84602 United States.
David J TophamDepartment of Chemistry and Biochemistry, Brigham Young University, Provo, Utah 84602 United States.
Jacob B NielsenDepartment of Chemistry and Biochemistry, Brigham Young University, Provo, Utah 84602 United States.
Gregory P NordinDepartment of Electrical and Computer Engineering, Brigham Young University, Provo, Utah 84602 United States.ORCID 0000-0001-7241-5764
Adam T WoolleyDepartment of Chemistry and Biochemistry, Brigham Young University, Provo, Utah 84602 United States.ORCID 0000-0002-4699-8094
Brigham Young University · US

Funding

High Density 3D Printed Microfluidics With Open Source Resins for Biomedical ApplicationsR15GM123405 · NIGMS · BRIGHAM YOUNG UNIVERSITY · PI NORDIN, GREGORY P. · 2017 to 2023
$1.3M
3D-Printed Integrated Microfluidic Devices for Preterm Birth Biomarker AnalysisR01EB027096 · NIBIB · BRIGHAM YOUNG UNIVERSITY · PI WOOLLEY, ADAM THOMAS · 2018 to 2021
$1.1M
NIBIB NIH HHS R01 EB027096NIGMS NIH HHS R15 GM123405
6 · The paper itself

Abstract

Solid-phase extraction (SPE) is a general preconcentration method for sample preparation that can be performed on a variety of specimens. The miniaturization of SPE within a 3D printed microfluidic device further allows for fast and simple extraction of analytes while also enabling integration of SPE with other sample preparation and separation methods. Here, we present the development and application of a reversed-phase lauryl methacrylate-based monolith, formed in 3D printed microfluidic devices, which can selectively retain peptides and proteins. The effectiveness of these SPE monoliths and 3D printed microfluidic devices was tested using a panel of nine preterm birth biomarkers of varying hydrophobicities and ranging in mass from 2 to 470 kDa. The biomarkers were selectively retained, fluorescently labeled, and eluted separately from the excess fluorescent label in 3D printed microfluidic systems. These are the first results demonstrating microfluidic analysis processes on a complete panel of preterm birth biomarkers, an important step toward developing a miniaturized, fully integrated analysis system.

Indexed as

FluorescenceLab-On-A-Chip DevicesPrinting, Three-DimensionalSolid Phase ExtractionBiomarkersFluorescent DyesHumansPremature BirthBiomarkersFluorescent Dyes

Identifiers

PMID32829631
PMCPMC7494619
OpenAlexW3080414955

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.