Evidence map›Paper›PMID 32825827›Full record

ArticleJournal of cardiothoracic surgery2020

Sternal reconstruction using locking compression plates (LCP): our experience in Egypt, a case series.

Kareem Ahmed, Mohamed Alaa Nady

Registry-linked trialOpen access · goldAbstract readCase Reports
In one paragraph

Article in Journal of cardiothoracic surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04092374 (Sternal Fracture Fixation by Locking Compression Plates), which is not on this map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.2field-weighted citation impact, top 45% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT04092374 naunknown statusnot on this map

Sternal Fracture Fixation by Locking Compression Plates (LCP) System

TypeinterventionalSponsorAssiut UniversityRan2019 to 2022Enrolled10ConditionsSternal FractureArmsLocking compression plates
3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 citations in OpenAlex.

  1. Article
  2. Article
  3. Thoracic surgery in Egypt.Journal of thoracic disease · 2022
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Kareem AhmedCardiothoracic Surgery Department, Assiut University Heart Hospital, Assiut, Egypt. kareemdna94@gmail.com.
Mohamed Alaa NadyCardiothoracic Surgery, Assiut University Heart Hospital, Assiut, Egypt.
Assiut University · EG

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSternal fractures are rare accounting for about 3-8% of traumatic chest. There are many lines of treatments for sternal fractures which can be classified as conservative or surgical. Surgical techniques include wire fixation and sternal plating. There are no standardization of indications for each line of management. We explore if sternal reconstruction using locking titanium plates and self-tapping screws provide the patient with the best chance of proper sternal healing avoiding chronic pain and its complications and allow the patient early mobilization and rapid restoring of his normal life at its maximum.

methodsOur inclusion criteria are patients of both gender from 20 to 60 years of age presented with traumatic sternal fracture at any site or pathological fracture due to metastatic or primary tumors infiltrating the sternum. High Associated Injury Scale scores were excluded. Exclusion criteria also included patients younger than 20 years or older than 60 years. Primary outcome is post-operative pain score and is measured using numerical pain scale ranging from zero to 10 where zero means there is no pain at all and ten is the worst imaginable pain ever.

resultsSternal reconstruction using titanium plates has proven to be an efficient method of stabilization with tremendous immediate relief of pain showed by the differences between pre-operative and post-operative pain scale scores in our patients (n = 5) with Median scores being 7 and 1.5 with range being from 7 to 9 and 1 to 3 respectively (p-value = .039). Operative time range between 150 min and 90 min with median of 120 min. Extubation of patients was smooth with no events with median time of extubation being 120 min. From our experience, there were no observed wound complications except at the third patient who suffered a small wound hematoma that was resolved by gentle compressing only and needed no further intervention.

conclusionWe recommend adopting sternal reconstruction using titanium plating systems more readily encouraging even larger clinical trials on the way to a clear guidelines. Plating systems show promising results with least pain, better stability, less complications and rapid, smooth recovery.

trial registrationNCT04092374.

Indexed as

Bone PlatesBone WiresAdultBone ScrewsEgyptFracture Fixation, InternalFractures, BoneHumansMaleMiddle AgedOperative TimeSternumSurgical Wound DehiscenceTitaniumWound HealingTitaniumFracturePainPlatesReconstructionScrewsSternumTitanium

Identifiers

PMID32825827
PMCPMC7441539
OpenAlexW3080985106

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials