Evidence map›Paper›PMID 32825744›Full record

ArticleHealthcare (Basel, Switzerland)2020

Determination of the Minimum Detectable Change in the Total and Segmental Volumes of the Upper Limb, Evaluated by Perimeter Measurements.

José Manuel Tánori-Tapia, Ena Monserrat Romero-Pérez, Néstor Antonio Camberos, Mario A Horta-Gim, Gabriel Núñez-Othón, Carlos Medina-Pérez, José Antonio de Paz

Open access · goldAbstract read
In one paragraph

Article in Healthcare (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
0.8field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it, 14 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Article
  4. Article
  5. Article
  6. Observational
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 2 countries.

José Manuel Tánori-TapiaDivision of Biological Sciences and Health, University of Sonora, Hermosillo 83000, Mexico.
Ena Monserrat Romero-PérezDivision of Biological Sciences and Health, University of Sonora, Hermosillo 83000, Mexico.
Néstor Antonio CamberosDivision of Biological Sciences and Health, University of Sonora, Hermosillo 83000, Mexico.
Mario A Horta-GimDivision of Biological Sciences and Health, University of Sonora, Hermosillo 83000, Mexico.
Gabriel Núñez-OthónDivision of Biological Sciences and Health, University of Sonora, Hermosillo 83000, Mexico.
Carlos Medina-PérezSciences Health School, University Isabel I, 09003 Burgos, Spain.
José Antonio de PazDivision of Biological Sciences and Health, University of Sonora, Hermosillo 83000, Mexico.ORCID 0000-0002-4389-1777
Universidad de Sonora · MXUniversidad Isabel I · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Among female breast cancer survivors, there is a high prevalence of lymphedema subsequent to axillary lymph node dissection and axillary radiation therapy. There are many methodologies available for the screening, diagnosis and follow-up of breast cancer survivors with or without lymphedema, the most common of which is the measurement of patients' arm circumference. The purpose of this study was to determine the intra-rater minimal detectable change (MDC) in the volume of the upper limb, both segmentally and globally, using circumference measurements for the evaluation of upper limb volume. In this study, 25 women who had received a unilateral mastectomy for breast cancer stage II or III participated. On two occasions separated by 15 min, the same researcher determined 11 perimeters for each arm at 4 cm intervals from the distal crease of the wrist in the direction of the armpit. The MDC at the segmental level ranged from 3.37% to 7.57% (2.7 to 14.6 mL, respectively) and was 2.39% (42.9 mL) at the global level of the arm; thus, minor changes in this value result in a high level of uncertainty in the interpretation of the results associated with the diagnosis of lymphedema and follow-up for presenting patients.

Indexed as

breast cancercircumference measurementlymphedemaminimal detectable changereliabilitystandard error of measurement

Identifiers

PMID32825744
PMCPMC7551255
OpenAlexW3080408872

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked