Physical Validation of a Residual Impedance Rejection Method during Ultra-Low Frequency Bio-Impedance Spectral Measurements.

Zoltan Vizvari, Nina Gyorfi, Akos Odry, Zoltan Sari, Mihaly Klincsik, Marin Gergics, Levente Kovacs, Anita Kovacs, Jozsef Pal, Zoltan Karadi and 2 more

Abstract readValidation Study
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Zoltan VizvariDepartment of Environmental Engineering, Faculty of Engineering and Information Technology, University of Pecs, Boszorkany str. 2, H-7624 Pecs, Hungary.ORCID 0000-0003-0313-9959
Nina GyorfiDepartment of Environmental Engineering, Faculty of Engineering and Information Technology, University of Pecs, Boszorkany str. 2, H-7624 Pecs, Hungary.ORCID 0000-0003-1479-8044
Akos OdryInstitute of Information Technology, University of Dunaujvaros, Tancsics M. str. 1/A, H-2401 Dunaujvaros, Hungary.ORCID 0000-0002-9554-9586
Zoltan SariDepartment of Information Technology, Faculty of Engineering and Information Technology, University of Pecs, Boszorkany str. 2, H-7624 Pecs, Hungary.
Mihaly KlincsikDepartment of Mathematics, Faculty of Engineering and Information Technology, University of Pecs, Boszorkany str. 2, H-7624 Pecs, Hungary.ORCID 0000-0003-2831-8750
Marin Gergics1st Department of Medicine, Clinical Centre, University of Pecs, Ifjusag str. 13, H-7624 Pecs, Hungary.ORCID 0000-0002-5404-9112
Levente KovacsPhysiological Controls Research Center, University Research and Innovation Cetner, Obuda University, Becsi str. 96/b, H-1034 Budapest, Hungary.ORCID 0000-0002-3188-0800
Anita KovacsDepartment of Environmental Engineering, Faculty of Engineering and Information Technology, University of Pecs, Boszorkany str. 2, H-7624 Pecs, Hungary.
Jozsef PalInstitute of Physiology, Medical School, University of Pecs, Szigeti str. 12, H-7624 Pecs, Hungary.ORCID 0000-0001-6468-6409
Zoltan KaradiInstitute of Physiology, Medical School, University of Pecs, Szigeti str. 12, H-7624 Pecs, Hungary.ORCID 0000-0003-4314-8921
Peter OdryInstitute of Information Technology, University of Dunaujvaros, Tancsics M. str. 1/A, H-2401 Dunaujvaros, Hungary.ORCID 0000-0003-2296-4508
Attila TothInstitute of Physiology, Medical School, University of Pecs, Szigeti str. 12, H-7624 Pecs, Hungary.ORCID 0000-0001-9433-7517

Funding

Pécsi Tudományegyetem EFOP-3.6.3-VEKOP-16-2017-00009Pécsi Tudományegyetem KA-2019-19Pécsi Tudományegyetem TUDFO/51757-1/2019-ITM
6 · The paper itself

Abstract

Accurate and reliable measurement of the electrical impedance spectrum is an essential requirement in order to draw relevant conclusions in many fields and a variety of applications; in particular, for biological processes. Even in the state-of-the-art methods developed for this purpose, the accuracy and efficacy of impedance measurements are reduced in biological systems, due to the regular occurrence of parameters causing measurement errors such as residual impedance, parasitic capacitance, generator anomalies, and so on. Recent observations have reported the necessity of decreasing such inaccuracies whenever measurements are performed in the ultra-low frequency range, as the above-mentioned errors are almost entirely absent in such cases. The current research work proposes a method which can reject the anomalies listed above when measuring in the ultra-low frequency range, facilitating data collection at the same time. To demonstrate our hypothesis, originating from the consideration of the determinant role of the measuring frequency, a physical model is proposed to examine the effectiveness of our method by measuring across the commonly used vs. ultra-low frequency ranges. Validation measurements reflect that the range of frequencies and the accuracy is much greater than in state-of-the-art methods. Using the proposed new impedance examination technique, biological system characterization can be carried out more accurately.

Indexed as

Electric ImpedanceElectric Capacitanceelectrical impedance spectrum measurementnon-invasive testing of biological structuresrejecting measurement errorsresidual impedances

Identifiers

PMID32825145
PMCPMC7506680

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.