Evidence map›Paper›PMID 32824415›Full record

ArticleSensors (Basel, Switzerland)2020

Designing and Implementing an Implantable Wireless Micromanometer System for Real-Time Bladder Pressure Monitoring: A Preliminary Study.

Yu-Ting Li, Ling-Yu Yang, Wei-Ting Hsu, Chih-Wei Peng

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Yu-Ting LiTaiwan Instrument Research Institute, National Applied Research Laboratories, Hsinchu 30261, Taiwan.
Ling-Yu YangSchool of Biomedical Engineering, College of Biomedical Engineering, Taipei Medical University, Taipei 11031, Taiwan.
Wei-Ting HsuTaiwan Instrument Research Institute, National Applied Research Laboratories, Hsinchu 30261, Taiwan.
Chih-Wei PengSchool of Biomedical Engineering, College of Biomedical Engineering, Taipei Medical University, Taipei 11031, Taiwan.ORCID 0000-0001-9744-4094

Funding

Ministry of Science and Technology, Taiwan MOST109-2221-E-492-005, 109-2811-E-038 -502 -MY3, and 108-2314-B-038 -017the Higher Education Sprout Project by the Ministry of Education, Taiwan DP2-108-21121-01-N-08-02
6 · The paper itself

Abstract

Many mini-implantable devices have been developed and fabricated for diagnostic and treatment purposes. Wireless implantable biomicrosystems provide a desirable approach for long-term physiological signal monitoring. In this study, we implemented a wireless implantable biomicrosystem for bladder-cavity pressure measurements in a freely moving rabbit. To manage the power more effectively, a magnetic reed switch was applied to turn on/off the implantable module using a neodymium-iron-boron (NdFeB) magnet. The measured bladder pressure signal was wirelessly transmitted from the implantable module to a host unit. Our results indicated that the implantable biomicrosystem exhibited satisfactory performance and safety, as evidenced by an error percentage of less than ±1% for pressure measurements and less than 2 °C of a temperature rise under normal operation. The wireless biomicrosystem was implanted into the bladder cavity of a rabbit. Bladder pressure was simultaneously measured by both the biomicrosystem and conventional cystometry in the animal. The two signals were similar during the voiding phase, with a correlation coefficient of 0.885. Additionally, the biomicrosystem coated with polydimethylsiloxane in this study showed no cytotoxicity, which confirmed its biocompatibility. In conclusion, we demonstrated a good biocompatible wireless biomicrosystem which showed good reproducibility with respect to pressure monitoring by conventional cystometry. Further studies are needed to confirm the results of this preliminary feasibility study for actual clinical applications.

Indexed as

Monitoring, PhysiologicUrinary BladderWireless TechnologyAnimalsProstheses and ImplantsRabbitsReproducibility of Resultsbiocompatibilitybladder pressureimplantable biomicrosystemwireless

Identifiers

PMID32824415
PMCPMC7472397

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked