Evidence map›Paper›PMID 32821095›Full record

ArticleInternational journal of nanomedicine2020

Bovine Meniscus Middle Zone Tissue: Measurement of Collagen Fibril Behavior During Compression.

Katie H Sizeland, Hannah C Wells, Nigel M Kirby, Adrian Hawley, Stephen T Mudie, Tim M Ryan, Richard G Haverkamp

Open access · goldAbstract read
In one paragraph

Article in International journal of nanomedicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.0field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 14 citations in OpenAlex.

  1. Anisotropic wear behavior of meniscus: Influence of cross-shear and loading magnitude.Journal of the mechanical behavior of biomedical materials · 2026
    Article
  2. PeerJ · 2025
    Article
  3. Article
  4. Article
  5. Natural biopolymer scaffold for meniscus tissue engineering.Frontiers in bioengineering and biotechnology · 2022
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 2 countries.

Katie H SizelandHuman Health, ANSTO, Lucas Heights, Sydney, NSW 2234, Australia.ORCID 0000-0001-8075-1901
Hannah C WellsSchool of Food and Advanced Technology, Massey University, Palmerston North 4472, New Zealand.
Nigel M KirbySAXS/WAXS Beamline, Australian Synchrotron, ANSTO, Clayton, Melbourne, VIC 3168, Australia.
Adrian HawleySAXS/WAXS Beamline, Australian Synchrotron, ANSTO, Clayton, Melbourne, VIC 3168, Australia.
Stephen T MudieSAXS/WAXS Beamline, Australian Synchrotron, ANSTO, Clayton, Melbourne, VIC 3168, Australia.ORCID 0000-0002-3331-970X
Tim M RyanSAXS/WAXS Beamline, Australian Synchrotron, ANSTO, Clayton, Melbourne, VIC 3168, Australia.
Richard G HaverkampSchool of Food and Advanced Technology, Massey University, Palmerston North 4472, New Zealand.ORCID 0000-0002-3890-7105
Australian Nuclear Science and Technology Organisation · AUMassey University · NZ

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundType I collagen is the major component of the extracellular matrix of the knee's meniscus and plays a central role in that joint's biomechanical properties. Repair and reconstruction of tissue damage often requires a scaffold to assist the body to rebuild. The middle zone of bovine meniscus is a material that may be useful for the preparation of extracellular matrix scaffolds.

methodsHere, synchrotron-based small-angle X-ray scattering (SAXS) patterns of bovine meniscus were collected during unconfined compression. Collagen fibril orientation, D-spacing, compression distance and force were measured.

resultsThe collagen fibrils in middle zone meniscal fibrocartilage become more highly oriented perpendicular to the direction of compression. The D-spacing also increases, from 65.0 to 66.3 nm with compression up to 0.43 MPa, representing a 1.8% elongation of collagen fibrils perpendicular to the compression.

conclusionThe elasticity of the collagen fibrils under tension along their length when the meniscus is compressed, therefore, contributes to the overall elastic response of the meniscus only under loads that exceed those likely to be experienced physiologically.

Indexed as

AnimalsBiomechanical PhenomenaCattleCollagenCollagen Type IElasticityMaleMenisci, TibialScattering, Small AngleStress, MechanicalSynchrotronsX-Ray DiffractionCollagenCollagen Type IcollagencompressionmeniscusSAXSscaffold

Identifiers

PMID32821095
PMCPMC7419642
OpenAlexW3044591645

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.