Evidence map›Paper›PMID 32820211›Full record

ArticleScientific reports2020

Performance demonstration of a hybrid Compton camera with an active pinhole for wide-band X-ray and gamma-ray imaging.

Akihisa Omata, Jun Kataoka, Kazuya Fujieda, Shogo Sato, Eri Kuriyama, Hiroki Kato, Atsushi Toyoshima, Takahiro Teramoto, Kazuhiro Ooe, Yuwei Liu and 5 more

Abstract read
In one paragraph

Article in Scientific reports, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Multiplexed imaging of radionuclides.Nature biomedical engineering · 2025
    Review
  2. Article
  3. Article
  4. Review
  5. Article
  6. Review
  7. Compton imaging for medical applications.Radiological physics and technology · 2022
    Review
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

15 authors.

Akihisa OmataGraduate School of Advanced Science and Engineering, Waseda University, Tokyo, Japan. omt22@fuji.waseda.jp.
Jun KataokaGraduate School of Advanced Science and Engineering, Waseda University, Tokyo, Japan.
Kazuya FujiedaGraduate School of Advanced Science and Engineering, Waseda University, Tokyo, Japan.
Shogo SatoGraduate School of Advanced Science and Engineering, Waseda University, Tokyo, Japan.
Eri KuriyamaGraduate School of Advanced Science and Engineering, Waseda University, Tokyo, Japan.
Hiroki KatoGraduate School of Medicine, Osaka University, Osaka, Japan.
Atsushi ToyoshimaInstitute for Radiation Science, Osaka University, Osaka, Japan.
Takahiro TeramotoInstitute for Radiation Science, Osaka University, Osaka, Japan.
Kazuhiro OoeGraduate School of Medicine, Osaka University, Osaka, Japan.
Yuwei LiuGraduate School of Medicine, Osaka University, Osaka, Japan.
Keiko MatsunagaGraduate School of Medicine, Osaka University, Osaka, Japan.
Takashi KamiyaGraduate School of Medicine, Osaka University, Osaka, Japan.
Tadashi WatabeGraduate School of Medicine, Osaka University, Osaka, Japan.
Eku ShimosegawaGraduate School of Medicine, Osaka University, Osaka, Japan.
Jun HatazawaGraduate School of Medicine, Osaka University, Osaka, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

X-ray and gamma-ray imaging are technologies with several applications in nuclear medicine, homeland security, and high-energy astrophysics. However, it is generally difficult to realize simultaneous wide-band imaging ranging from a few tens of keV to MeV because different interactions between photons and the detector material occur, depending on the photon energies. For instance, photoabsorption occurs below 100 keV, whereas Compton scattering dominates above a few hundreds of keV. Moreover, radioactive sources generally emit both X-ray and gamma-ray photons. In this study, we develop a "hybrid" Compton camera that can simultaneously achieve X-ray and gamma-ray imaging by combining features of "Compton" and "pinhole" cameras in a single detector system. Similar to conventional Compton cameras, the detector consists of two layers of scintillator arrays with the forward layer acting as a scatterer for high-energy photons (> 200 keV) and an active pinhole for low-energy photons (< 200 keV). The experimental results on the performance of the hybrid camera were consistent with those from the Geant4 simulation. We simultaneously imaged [Formula: see text]Am (60 keV) and [Formula: see text]Cs (662 keV) in the same field of view, achieving an angular resolution of 10[Formula: see text] (FWHM) for both sources. In addition, imaging of [Formula: see text]At was conducted for the application in future nuclear medicine, particularly radionuclide therapy. The initial demonstrative images of the [Formula: see text]At phantom were reconstructed using the pinhole mode (using 79 keV) and Compton mode (using 570 keV), exhibiting significant similarities in source-position localization. We also verified that a mouse injected with 1 MBq of [Formula: see text]At can be imaged via pinhole-mode measurement in an hour.

Identifiers

PMID32820211
PMCPMC7441182

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.