ArticleKorean journal of anesthesiology2021
Four different methods of measuring cardiac index during cytoreductive surgery and hyperthermic intraperitoneal chemotherapy.
Article in Korean journal of anesthesiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 1 synthesis or guideline pooled it, 5 citations in OpenAlex.
- Agreement of minimally invasive pulse wave analysis with pulmonary artery and transpulmonary thermodilution cardiac output measurements in perioperative and intensive care medicine: a systematic review and meta-analysis.British journal of anaesthesia · 2026Pooled it
- A Novel Method for Cardiac Output and Vascular Parameters Estimation Using Peripheral Arterial Waveforms: Integrating Windkessel Model viaAnnals of biomedical engineering · 2026Article
- Comparison of parameter types for the calibration of noninvasive continuous cardiac output monitoring of patients undergoing lumbar spinal surgery in the prone position.Technology and health care : official journal of the European Society for Engineering and Medicine · 2023Article
- Comparison between Fourth-Generation FloTrac/Vigileo System and Continuous Thermodilution Technique for Cardiac Output Estimation after Time Adjustment during Off-Pump Coronary Artery Bypass Graft Surgery: A Retrospective Cohort Study.Journal of clinical medicine · 2022Article
- Non-Invasive Continuous Measurement of Haemodynamic Parameters-Clinical Utility.Journal of clinical medicine · 2021Review
- Anesthetic concerns during cytoreductive surgery with hyperthermic intraperitoneal chemotherapy.Korean journal of anesthesiology · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundCytoreductive surgery (CRS) and hyperthermic intraperitoneal chemotherapy (HIPEC) are high-risk extensive abdominal surgery. During high-risk surgery, less invasive methods for cardiac index (CI) measurement have been widely used in operating theater. We investigated the accuracy of CI derived from different methods (FroTrac, ProAQT, ClearSight, and arterial pressure waveform analysis [APWA], from PICCO) and compared them to transpulmonary thermodilution (TPTD) during CRS and HIPEC in the operative room and intensive care unit (ICU).
methodsTwenty-five patients scheduled for CRS-HIPEC were enrolled. During nine predefined time-points, simultaneous hemodynamic measurements were performed in the operating room and ICU. Absolute and relative changes of CI were analyzed using a Bland-Altman plot, four-quadrant plot, and interchangeability.
resultsThe mean bias was -0.1 L/min/m2 for ClearSight, ProAQT, and APWA and was -0.2 L/min/m2 for FloTrac compared with TPTD. All devices had large limits of agreement (LoA). The percentage of errors and interchangeabilities for ClearSight, FloTrac, ProAQT, and APWA were 50%, 50%, 54%, 36% and 36%, 47%, 40%, 72%, respectively. Trending capabilities expressed as concordance using clinically significant CI changes were -7º ± 39º, -19º ± 38º, -13º ± 41º, and -15º ± 39º. Interchangeability in trending showed low percentages of interchangeable and gray zone data pairs for all devices.
conclusionsDuring CRS-HIPEC, ClearSight, FloTrac and ProAQT systems were not able to reliably measure CI compared to TPTD. Reproducibility of changes over time using concordance, angular bias, radial LoA, and interchangeability in trending of all devices was unsatisfactory.
Indexed as