Evidence map›Paper›PMID 32817913›Full record

ArticleBioactive materials2021

The mechanical property and corrosion resistance of Mg-Zn-Nd alloy fine wires

Ming Gao, Di Na, Xiangqiao Ni, Lihui Song, Iniobong P Etim, Ke Yang, Lili Tan, Zheng Ma

Open access · goldAbstract read
In one paragraph

Article in Bioactive materials, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
1.4field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 31 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Research status and prospects of biodegradable magnesium-based metal guided bone regeneration membranes.Hua xi kou qiang yi xue za zhi = Huaxi kouqiang yixue zazhi = West China journal of stomatology · 2024
    Review
  7. Article
  8. Article
  9. Article
  10. Review
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Ming GaoSchool of Materials Science and Engineering, University of Science and Technology of China, Shenyang, 110016, China.
Di NaThe First Hospital of China Medical University, Department of Surgical Oncology, China.
Xiangqiao NiThe First Hospital of China Medical University, Department of Surgical Oncology, China.
Lihui SongThe First Hospital of China Medical University, Department of Surgical Oncology, China.
Iniobong P EtimSchool of Materials Science and Engineering, University of Science and Technology of China, Shenyang, 110016, China.
Ke YangInstitute of Metal Research, Chinese Academy of Sciences, Shenyang, 110016, China.
Lili TanInstitute of Metal Research, Chinese Academy of Sciences, Shenyang, 110016, China.
Zheng MaInstitute of Metal Research, Chinese Academy of Sciences, Shenyang, 110016, China.
Chinese Academy of Sciences · CNFirst Hospital of China Medical University · CNUniversity of Science and Technology of China · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Titanium and its alloy are commonly used as surgical staples in the reconstruction of intestinal tract and stomach, however they cannot be absorbed in human body, which may cause a series of complications to influence further diagnosis. Magnesium and its alloy have great potential as surgical staples, because they can be degraded in human body and have good mechanical properties and biocompatibility. In this study, Mg-2Zn-0.5Nd (ZN20) alloy fine wires showed great potential as surgical staples. The ultimate tensile strength and elongation of ZN20 alloy fine wires were 248 MPa and 13%, respectively, which could be benefit for the deformation of the surgical staples from U-shape to B-shape. The bursting pressure of the wire was about 40 kPa, implying that it can supply sufficient mechanical support after anastomosis. Biochemical test and histological analysis illustrated good biocompatibility and biological safety of ZN20 alloy fine wire. The residual tensile stress formed on the outside of ZN20 fine wire during drawing would accelerate the corrosion. The second phase had a negative influence on corrosion property due to galvanic corrosion. The corrosion rate

Indexed as

AnastomosisCorrosion resistanceIn vivoMagnesiumSurgical staple

Identifiers

PMID32817913
PMCPMC7419589
OpenAlexW3048024963

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390