Evidence map›Paper›PMID 32817715›Full record

ArticlePloS one2020

Evaluation of wearing comfort of dust masks.

Sejin Choi, Ryeol Park, Nahmkeon Hur, Wonjung Kim

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.1field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 16 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Speech Impaired by Half Masks Used for the Respiratory Tract Protection.International journal of environmental research and public health · 2022
    Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Sejin ChoiDepartment of Mechanical Engineering, Sogang University, Seoul, Republic of Korea.
Ryeol ParkDepartment of Mechanical Engineering, Sogang University, Seoul, Republic of Korea.
Nahmkeon HurDepartment of Mechanical Engineering, Sogang University, Seoul, Republic of Korea.
Wonjung KimDepartment of Mechanical Engineering, Sogang University, Seoul, Republic of Korea.ORCID 0000-0002-6866-6840
Sogang University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Dust masks are widely used to prevent the inhalation of particulate matter into the human respiratory organs in polluted air environments. The filter of a dust mask inherently obstructs the natural respiratory air flows, and this flow resistance is mainly responsible for the discomfort experienced when wearing a dust mask. In atmospheric conditions seriously contaminated with fine dust, it is recommended that common citizens wear a dust mask in their everyday lives, yet many people are reluctant to wear a dust mask owing to the discomfort experienced when wearing it for a long time. Understanding of physical reasons for the discomfort is thus crucial in designing a dust mask, but remains far from clear. This study presents a technique to quantify the wearing comfort of dust masks. By developing a respiration simulator to measure the pressure loss across a dust mask, we assessed the energy costs to overcome flow resistance when breathing through various types of dust masks. The energy cost for a single inhalation varies with the mask type in a range between 0 and 10 mJ. We compared the results with the survey results of 40 people about the wearing comfort of the dust masks, which revealed that the wearing comfort crucially depends on the energy cost required for air inhalation though the dust mask. Using the measured energy cost during inhalation as a parameter to quantify the wearing comfort, we present a comprehensive evaluation of the performance of dust masks in terms of not only the filtering performance but also the wearing comfort. Our study suggests some design principles for dust mask filters, auxiliary electric fans, and check valves.

Indexed as

RespirationAdultDustEarFemaleFiltrationHumansInhalationMaleMasksMiddle AgedParticulate MatterRespiratory Protective DevicesDustParticulate Matter

Identifiers

PMID32817715
PMCPMC7446894
OpenAlexW3081334319

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.