Evidence map›Paper›PMID 32817653›Full record

ArticlePloS one2020

A simultaneous optical and electrical in-vitro neuronal recording system to evaluate microelectrode performance.

Zaid Aqrawe, Nitish Patel, Yukti Vyas, Mahima Bansal, Johanna Montgomery, Jadranka Travas-Sejdic, Darren Svirskis

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.0field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. An open-source transparent microelectrode array.Journal of neural engineering · 2022
    Article
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Zaid AqraweSchool of Pharmacy, The University of Auckland, Auckland, New Zealand.ORCID 0000-0002-8650-0975
Nitish PatelDepartment of Electrical and Computer Engineering, The University of Auckland, Auckland, New Zealand.ORCID 0000-0002-3459-5407
Yukti VyasDepartment of Physiology and Center for Brain Research, The University of Auckland, Auckland, New Zealand.
Mahima BansalSchool of Pharmacy, The University of Auckland, Auckland, New Zealand.
Johanna MontgomeryDepartment of Physiology and Center for Brain Research, The University of Auckland, Auckland, New Zealand.
Jadranka Travas-SejdicSchool of Chemical Sciences and MacDiarmid Institute for Advanced Materials and Nanotechnology, The University of Auckland, Auckland, New Zealand.
Darren SvirskisSchool of Pharmacy, The University of Auckland, Auckland, New Zealand.
University of Auckland · NZ

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesIn this paper, we aim to detail the setup of a high spatio-temporal resolution, electrical recording system utilising planar microelectrode arrays with simultaneous optical imaging suitable for evaluating microelectrode performance with a proposed 'performance factor' metric.

methodsTechniques that would facilitate low noise electrical recordings were coupled with voltage sensitive dyes and neuronal activity was recorded both electrically via a customised amplification system and optically via a high speed CMOS camera. This technique was applied to characterise microelectrode recording performance of gold and poly(3,4-ethylenedioxythiophene)/polystyrene sulfonate (PEDOT/PSS) coated electrodes through traditional signal to noise (SNR) calculations as well as the proposed performance factor.

resultsNeuronal activity was simultaneously recorded using both electrical and optical techniques and this activity was confirmed via tetrodotoxin application to inhibit action potential firing. PEDOT/PSS outperformed gold using both measurements, however, the performance factor metric estimated a 3 fold improvement in signal transduction when compared to gold, whereas SNR estimated an 8 fold improvement when compared to gold.

conclusionThe design and functionality of a system to record from neurons both electrically, through microelectrode arrays, and optically via voltage sensitive dyes was successfully achieved. SIGNIFICANCE: The high spatiotemporal resolution of both electrical and optical methods will allow for an array of applications such as improved detection of subthreshold synaptic events, validation of spike sorting algorithms and a provides a robust evaluation of extracellular microelectrode performance.

Indexed as

Electrodes, ImplantedMicroelectrodesAction PotentialsAlgorithmsGoldHumansNeuronsPolymersSignal TransductionGoldPolymers

Identifiers

PMID32817653
PMCPMC7440637
OpenAlexW3081499938