ArticleMagnetic resonance in medicine2021

Investigating cardiac stimulation limits of MRI gradient coils using electromagnetic and electrophysiological simulations in human and canine body models.

Valerie Klein, Mathias Davids, Lothar R Schad, Lawrence L Wald, Bastien Guérin

Erratum issuedAbstract read
In one paragraph

Article in Magnetic resonance in medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Engineering clinical translation of OGSE diffusion MRI.Magnetic resonance in medicine · 2025
    Review
  5. Review
  6. Article
  7. Article
  8. Article
  9. Safety of MRI in patients with retained cardiac leads.Magnetic resonance in medicine · 2022
    Article
  10. Review
  11. Review
  12. Review
  13. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors.

Valerie KleinComputer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany.ORCID 0000-0002-7600-6172
Mathias DavidsComputer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany.ORCID 0000-0003-0217-9123
Lothar R SchadComputer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany.
Lawrence L WaldA. A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, Massachusetts, USA.ORCID 0000-0001-8278-6307
Bastien GuérinA. A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, Massachusetts, USA.ORCID 0000-0002-4746-0886

Funding

CONNECTOME 2.0: DEVELOPING THE NEXT GENERATION HUMAN MRI SCANNER FOR BRIDGING STUDIES OF THE MICRO-, MESO- AND MACRO-CONNECTOMEU01EB026996 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI BASSER, PETER J., HUANG, SUSIE YI · 2018 to 2022
$14.2M
MRI CORTICOGRAPHY: DEVELOPING NEXT GENERATION MICROSCALE HUMAN CORTEX MRI SCANNERU01EB025162 · NIBIB · UNIVERSITY OF CALIFORNIA BERKELEY · PI FEINBERG, DAVID ALAN, LIU, CHUNLEI · 2017 to 2021
$13.4M
A magnetic particle imager (MPI) for functional brain imaging in humansU01EB025121 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI WALD, LAWRENCE L · 2017 to 2022
$6.1M
Mitigation of peripheral nerve stimulation (PNS) in MRIR01EB028250 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI Bastien Guerin · 2020 to 2026
$3.6M
Neuroimaging of deep brain stimulation patients using safe MRI excitationsR00EB019482 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI GUERIN, BASTIEN · 2017 to 2019
$747k
NIBIB NIH HHS R00 EB019482NIBIB NIH HHS R01 EB028250NIBIB NIH HHS U01 EB025121NIBIB NIH HHS U01 EB025162NIBIB NIH HHS U01 EB026996
6 · The paper itself

Abstract

purposeCardiac stimulation (CS) limits to gradient coil switching speed are difficult to measure in humans; instead, current regulatory guidelines (IEC 60601-2-33) are based on animal experiments and electric field-to-dB/dt conversion factors computed for a simple, homogeneous body model. We propose improvement to this methodology by using more detailed CS modeling based on realistic body models and electrophysiological models of excitable cardiac fibers.

methodsWe compute electric fields induced by a solenoid, coplanar loops, and a commercial gradient coil in two human body models and a canine model. The canine simulations mimic previously published experiments. We generate realistic fiber topologies for the cardiac Purkinje and ventricular muscle fiber networks using rule-based algorithms, and evaluate CS thresholds using validated electrodynamic models of these fibers.

resultsWe were able to reproduce the average measured canine CS thresholds within 5%. In all simulations, the Purkinje fibers were stimulated before the ventricular fibers, and therefore set the effective CS threshold. For the investigated gradient coil, simulated CS thresholds for the x-, y-, and z-axis were at least one order of magnitude greater than the International Electrotechnical Commission limit.

conclusionWe demonstrate an approach to simulate gradient-induced CS using a combination of electromagnetic and electrophysiological modeling. Pending additional validation, these simulations could guide the assessment of CS limits to MRI gradient coil switching speed. Such an approach may lead to less conservative, but still safe, operation limits, enabling the use of the maximum gradient amplitude versus slew rate parameter space of recent, powerful gradient systems.

Indexed as

Electromagnetic PhenomenaMagnetic Resonance ImagingAlgorithmsAnimalsCardiac ElectrophysiologyDogsElectromagnetic FieldsHumanscardiac stimulationelectromagnetic exposure safetyelectromagnetic field simulationheart modelmagnetostimulation thresholdsMRI gradient field switching