Evidence map›Paper›PMID 32811519›Full record

Observational studyRadiation oncology (London, England)2020

Intra-fraction and Inter-fraction analysis of a dedicated immobilization device for intracranial radiation treatment.

Chin Loon Ong, Niccolò Giaj-Levra, Luca Nicosia, Vanessa Figlia, Davide Tomasini, Eric M Franken, Filippo Alongi

Open access · goldAbstract readMulticenter StudyObservational Study
In one paragraph

Observational study in Radiation oncology (London, England), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.3field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Chin Loon OngDepartment of Radiotherapy, HagaZiekenhuis, Den Haag, The Netherlands.
Niccolò Giaj-LevraAdvanced Radiation Oncology Department, IRCCS Sacro Cuore Don Calabria Hospital, Via Don A.Sempreboni 5, 37024, Negrar di Valpolicella, Verona, Italy. niccolo.giajlevra@sacrocuore.it.ORCID http://orcid.org/0000-0002-4328-0319
Luca NicosiaAdvanced Radiation Oncology Department, IRCCS Sacro Cuore Don Calabria Hospital, Via Don A.Sempreboni 5, 37024, Negrar di Valpolicella, Verona, Italy.
Vanessa FigliaAdvanced Radiation Oncology Department, IRCCS Sacro Cuore Don Calabria Hospital, Via Don A.Sempreboni 5, 37024, Negrar di Valpolicella, Verona, Italy.
Davide TomasiniRadiation Oncology Department, ASST Spedali Civili di Brescia, University of Brescia, Brescia, Italy.
Eric M FrankenDepartment of Radiotherapy, HagaZiekenhuis, Den Haag, The Netherlands.
Filippo AlongiAdvanced Radiation Oncology Department, IRCCS Sacro Cuore Don Calabria Hospital, Via Don A.Sempreboni 5, 37024, Negrar di Valpolicella, Verona, Italy.
Ospedale Sacro Cuore Don Calabria · ITHaga Hospital · NLAzienda Socio Sanitaria Territoriale degli Spedali Civili di Brescia · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundImmobilization devices are crucial to minimize patient positioning uncertainties in radiotherapy (RT) treatments. Accurate inter and intra-fraction motions is particularly important for intracranial and stereotactic radiation treatment which require high precision in dose delivery. Recently, a new immobilization device has been developed specifically for the radiation treatment of intracranial malignancies. To date, no data are available on the use of this device in daily clinical practice. The aim of this study is to investigate the intra and inter-fraction variations, patient comfort and radiographer confidence of the immobilization system from two distinct institutions: HagaZiekenhuis, Den Haag, Netherlands and IRCCS Ospedale Sacro Cuore Don Calabria, Negrar, Italy. MATERIAL AND

methodSixteen patients (10 diagnosed with brain metastases and 6 with primary central nervous systemic tumor) from IRCCS Ospedale Sacro Cuore Don Calabria and 17 patients (all diagnosed with brain metastases tumor) from HagaZiekenhuis were included in this study. The median target volume was 436 cc (range 3.2-1628 cc) and 4.58 cc (range 0.4-27.19 cc) for IRCCS and Haga, respectively. For patients treated in IRCCS Sacro Cuore Don Calabria, the median dose prescription was 30 Gy (range 27-60 Gy) and median number of fractions 10 (range 3-30). In Haga the median dose prescription was 21 Gy (range 8-21 Gy) and the median number of fraction was 1 (range 1-3). The immobilization device was assembled during CT simulation. A short interview to the patient regarding the device's comfort level was conducted at the end of the simulation procedure. Additionally, simulation setup time and radiographer (RTT) procedures (i.e. mask preparation) were evaluated. Prior to radiation treatment delivery, an automatic rigid match on the cranial bones between cone beam computed tomography (CBCT) and planning-CT was performed. A couch shift was performed subsequently. An extra post-treatment CBCT was acquire after the treatment delivery. This post-treatment CBCT was matched with pre-treatment CBCT to identify any possible intra-fraction motion. All online matches were validated by experienced radiation oncologist or RTT. A total of 126 CBCT's were analyzed offline by radiation oncologist/medical physicist. The data of the pre-treatment CBCT match was used to quantify inter-fraction motion. The post-treatment CBCT was matched with pre-treatment CBCT to identify any possible intra-fraction motion.

resultsDuring the molding of the mask, all patients responded positive to the comfort. Median time required by the RTTs to assemble the immobilization system was 9 min (range 6-12 min). In terms of comfort, all patients reported a good-to high level of satisfaction. The RTTs also respond positively towards the use of the locking mechanism and clips. Results of positioning uncertainties were comparable between the two institutes. The mean inter-fraction motion for all translational and rotational directions were < 2 mm (SD < 4 mm) and < 0.5°(SD < 1.5°), respectively, while the mean intra-fraction motions were < 0.4 mm (SD < 0.6 mm) and 0.3° (SD < 0.5°).

conclusionsThis study demonstrates the efficacy and feasibility of the immobilization device in the intracranial radiation treatment. Both patient comfort and preparation time by RTTs are considered adequate. In combination with online daily imaging procedure, this device can achieve submillimeter accuracy required for intracranial and stereotactic treatments.

Indexed as

ImmobilizationPatient PositioningAdolescentAdultAgedAged, 80 and overBrain NeoplasmsCentral Nervous System NeoplasmsCone-Beam Computed TomographyFemaleHumansImage Processing, Computer-AssistedItalyMaleMiddle AgedMovementBrainImmobilizationInter-fractionIntra-fractionRadiotherapy

Identifiers

PMID32811519
PMCPMC7437162
OpenAlexW3057770168

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.