In one paragraph

Article in Journal of the Royal Society, Interface, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Arghavan ArafatiThe Edwards Lifesciences Center for Advanced Cardiovascular Technology, University of California, 2410 Engineering Hall, Irvine, CA 92697-2730, USA.
Daisuke MorisawaThe Edwards Lifesciences Center for Advanced Cardiovascular Technology, University of California, 2410 Engineering Hall, Irvine, CA 92697-2730, USA.
Michael R AvendiThe Edwards Lifesciences Center for Advanced Cardiovascular Technology, University of California, 2410 Engineering Hall, Irvine, CA 92697-2730, USA.
M Reza AminiLoma Linda University Medical Center, Loma Linda, CA 92354, USA.
Ramin A AssadiDivision of Cardiology, David Geffen School of Medicine at UCLA, Los Angeles, CA 90095, USA.
Hamid JafarkhaniCenter for Pervasive Communications and Computing, University of California, 4217 Engineering Hall, Irvine, CA 92697-2700, USA.
Arash KheradvarThe Edwards Lifesciences Center for Advanced Cardiovascular Technology, University of California, 2410 Engineering Hall, Irvine, CA 92697-2730, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A major issue in translation of the artificial intelligence platforms for automatic segmentation of echocardiograms to clinics is their generalizability. The present study introduces and verifies a novel generalizable and efficient fully automatic multi-label segmentation method for four-chamber view echocardiograms based on deep fully convolutional networks (FCNs) and adversarial training. For the first time, we used generative adversarial networks for pixel classification training, a novel method in machine learning not currently used for cardiac imaging, to overcome the generalization problem. The method's performance was validated against manual segmentations as the ground-truth. Furthermore, to verify our method's generalizability in comparison with other existing techniques, we compared our method's performance with a state-of-the-art method on our dataset in addition to an independent dataset of 450 patients from the CAMUS (cardiac acquisitions for multi-structure ultrasound segmentation) challenge. On our test dataset, automatic segmentation of all four chambers achieved a dice metric of 92.1%, 86.3%, 89.6% and 91.4% for LV, RV, LA and RA, respectively. LV volumes' correlation between automatic and manual segmentation were 0.94 and 0.93 for end-diastolic volume and end-systolic volume, respectively. Excellent agreement with chambers' reference contours and significant improvement over previous FCN-based methods suggest that generative adversarial networks for pixel classification training can effectively design generalizable fully automatic FCN-based networks for four-chamber segmentation of echocardiograms even with limited number of training data.

Indexed as

Artificial IntelligenceImage Processing, Computer-AssistedHeartHumansMachine LearningNeural Networks, Computerartificial intelligencedeep learningechocardiographyfully automated segmentationgenerative adversarial networkmachine learning

Identifiers

PMID32811299
PMCPMC7482559

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.