Evidence map›Paper›PMID 32809176›Full record

ArticleJournal of medical systems2020

Design of a Dynamic Force Measurement System for Training and Evaluation of Suture Surgical Skills.

Fernando Pérez-Escamirosa, Salvador Montoya-Alvarez, Ricardo Manuel Ordorica-Flores, Luis Padilla-Sánchez, José Luis Jiménez-Corona, Jorge Ruíz-Lizarraga, Arturo Minor-Martínez

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of medical systems, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Fernando Pérez-EscamirosaInstituto de Ciencias Aplicadas y Tecnología (ICAT), Universidad Nacional Autónoma de México (UNAM), Circuito Exterior S/N, Ciudad Universitaria, Coyoacán, 04510, Ciudad de México, Mexico.ORCID https://orcid.org/0000-0001-7886-8692
Salvador Montoya-AlvarezSección de Bioelectrónica, Departamento de Ingeniería Eléctrica, Centro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional (CINVESTAV-IPN), Av. Instituto Politécnico Nacional No. 2508, Col. San Pedro Zacatenco, 07360, Ciudad de México, Mexico. salvador.montoyaa@cinvestav.mx.ORCID https://orcid.org/0000-0002-9906-3639
Ricardo Manuel Ordorica-FloresDepartamento de Cirugía Endoscópica, Hospital Infantil de México Federico Gómez, Calle Dr. Márquez No. 162, Cuahtémoc, Doctores, 06720, Ciudad de México, Mexico.
Luis Padilla-SánchezServicio de Cirugía Experimental, Unidad de Microcirugía, CMN 20 de Noviembre ISSSTE, Félix Cuevas 540, Col. del Valle Sur, 03100, Ciudad de México, Mexico.
José Luis Jiménez-CoronaDepartamento de Cirugía, Facultad de Medicina, Universidad Nacional Autónoma de México (UNAM), Circuito Interior, Av. Universidad 3000, Ciudad Universitaria, Coyoacán, 04510, Ciudad de México, Mexico.
Jorge Ruíz-LizarragaHospital Ángeles Pedregal, Camino de Sta Teresa 1055-S, Héroes de Padierna, La Magdalena Contreras, 10700, Ciudad de México, Mexico.
Arturo Minor-MartínezSección de Bioelectrónica, Departamento de Ingeniería Eléctrica, Centro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional (CINVESTAV-IPN), Av. Instituto Politécnico Nacional No. 2508, Col. San Pedro Zacatenco, 07360, Ciudad de México, Mexico.ORCID https://orcid.org/0000-0001-5365-5957

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The aim of this study is to present the SurgeForce system, a tissue handling training device for analysis of dynamic force applied to the tissue and objective assessment of basic surgical skills during the suture process. The SurgeForce system consists of a mechanical base formed by two platforms joint with three stainless steel springs and a three axial digital accelerometer attached to the upper platform, which detects the dynamic force caused by a surgeon when performing a suture task over a synthetic tissue pad. Accelerometer data is sent to a control unit where preprocessing to transform the raw data into a force signal is done, and then, the force signal is sent to a computer application, which register the force exerted over the synthetic tissue pad. For validation, 17 participants (6 surgeons and 11 medical students) performed three simple interrupted sutures with knot tying using the SurgeForce system. Ten force-based metrics were proposed to evaluate their performance during the suturing task. Results of the validation showed statistical differences in 8 of 10 force-based parameters for assessment of basic surgical skills during the suture task. The SurgeForce system demonstrated its capacity to differentiate force-based performance of surgeons and medical students. The SurgeForce system has been successfully validated. This system was able to distinguish force performance between experts and novices, showing its potential to distinguish surgeons with basic suture skills from those who are not yet prepared.

Indexed as

LaparoscopyStudents, MedicalSurgeonsClinical CompetenceHumansSuturesSuture TechniquesDynamicForceMeasurementsSkillsSurgeryTraining

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.