Evidence map›Paper›PMID 32807815›Full record

ArticleScientific reports2020

Development and validation of a sample entropy-based method to identify complex patient-ventilator interactions during mechanical ventilation.

Leonardo Sarlabous, José Aquino-Esperanza, Rudys Magrans, Candelaria de Haro, Josefina López-Aguilar, Carles Subirà, Montserrat Batlle, Montserrat Rué, Gemma Gomà, Ana Ochagavia and 2 more

Erratum issuedAbstract readValidation Study
In one paragraph

Article in Scientific reports, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

12 authors.

Leonardo Sarlabous *Critical Care Center, Hospital Universitari Parc Taulí, Institut d'Investigació i Innovació Parc Taulí I3PT, Universitat Autònoma de Barcelona, Parc Taulí 1, 08208, Sabadell, Barcelona, Spain. lsarlabous@tauli.cat.
José Aquino-Esperanza *Critical Care Center, Hospital Universitari Parc Taulí, Institut d'Investigació i Innovació Parc Taulí I3PT, Universitat Autònoma de Barcelona, Parc Taulí 1, 08208, Sabadell, Barcelona, Spain.
Rudys MagransBetterCare S.L, Sabadell, Spain.
Candelaria de HaroCritical Care Center, Hospital Universitari Parc Taulí, Institut d'Investigació i Innovació Parc Taulí I3PT, Universitat Autònoma de Barcelona, Parc Taulí 1, 08208, Sabadell, Barcelona, Spain.
Josefina López-AguilarCritical Care Center, Hospital Universitari Parc Taulí, Institut d'Investigació i Innovació Parc Taulí I3PT, Universitat Autònoma de Barcelona, Parc Taulí 1, 08208, Sabadell, Barcelona, Spain.
Carles SubiràDepartment of Intensive Care, Fundació Althaia, Universitat Internacional de Catalunya , Manresa, Spain.
Montserrat BatlleDepartment of Intensive Care, Fundació Althaia, Universitat Internacional de Catalunya , Manresa, Spain.
Montserrat RuéDepartment of Basic Medical Sciences, Universitat de Lleida-IRBLLEIDA, Lleida, Spain.
Gemma GomàCritical Care Center, Hospital Universitari Parc Taulí, Institut d'Investigació i Innovació Parc Taulí I3PT, Universitat Autònoma de Barcelona, Parc Taulí 1, 08208, Sabadell, Barcelona, Spain.
Ana OchagaviaCritical Care Center, Hospital Universitari Parc Taulí, Institut d'Investigació i Innovació Parc Taulí I3PT, Universitat Autònoma de Barcelona, Parc Taulí 1, 08208, Sabadell, Barcelona, Spain.
Rafael FernándezBiomedical Research Networking Center in Respiratory Disease (CIBERES), Instituto de Salud Carlos III, Madrid, Spain.
Lluís BlanchCritical Care Center, Hospital Universitari Parc Taulí, Institut d'Investigació i Innovació Parc Taulí I3PT, Universitat Autònoma de Barcelona, Parc Taulí 1, 08208, Sabadell, Barcelona, Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Patient-ventilator asynchronies can be detected by close monitoring of ventilator screens by clinicians or through automated algorithms. However, detecting complex patient-ventilator interactions (CP-VI), consisting of changes in the respiratory rate and/or clusters of asynchronies, is a challenge. Sample Entropy (SE) of airway flow (SE-Flow) and airway pressure (SE-Paw) waveforms obtained from 27 critically ill patients was used to develop and validate an automated algorithm for detecting CP-VI. The algorithm's performance was compared versus the gold standard (the ventilator's waveform recordings for CP-VI were scored visually by three experts; Fleiss' kappa = 0.90 (0.87-0.93)). A repeated holdout cross-validation procedure using the Matthews correlation coefficient (MCC) as a measure of effectiveness was used for optimization of different combinations of SE settings (embedding dimension, m, and tolerance value, r), derived SE features (mean and maximum values), and the thresholds of change (Th) from patient's own baseline SE value. The most accurate results were obtained using the maximum values of SE-Flow (m = 2, r = 0.2, Th = 25%) and SE-Paw (m = 4, r = 0.2, Th = 30%) which report MCCs of 0.85 (0.78-0.86) and 0.78 (0.78-0.85), and accuracies of 0.93 (0.89-0.93) and 0.89 (0.89-0.93), respectively. This approach promises an improvement in the accurate detection of CP-VI, and future study of their clinical implications.

Indexed as

EntropyVentilators, MechanicalAgedAPACHEAutomationFemaleHumansMaleMiddle AgedRespiration, ArtificialRheology

Identifiers

PMID32807815
PMCPMC7431581

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.