Evidence map›Paper›PMID 32807106›Full record

Trial reportBMC anesthesiology2020

Flexible fibreoptic intubation in swine - improvement for resident training and animal safety alike.

Robert Ruemmler, Alexander Ziebart, Thomas Ott, Dagmar Dirvonskis, Erik Kristoffer Hartmann

Open access · goldAbstract readRandomized Controlled Trial
In one paragraph

Trial report in BMC anesthesiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.5field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 5 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Robert RuemmlerDepartment of Anaesthesiology, Medical Centre of the Johannes Gutenberg-University, Langenbeckstrasse 1, 55131, Mainz, Germany. Robert.ruemmler@email.de.ORCID 0000-0002-9265-6052
Alexander ZiebartDepartment of Anaesthesiology, Medical Centre of the Johannes Gutenberg-University, Langenbeckstrasse 1, 55131, Mainz, Germany.
Thomas OttDepartment of Anaesthesiology, Medical Centre of the Johannes Gutenberg-University, Langenbeckstrasse 1, 55131, Mainz, Germany.
Dagmar DirvonskisDepartment of Anaesthesiology, Medical Centre of the Johannes Gutenberg-University, Langenbeckstrasse 1, 55131, Mainz, Germany.
Erik Kristoffer HartmannDepartment of Anaesthesiology, Medical Centre of the Johannes Gutenberg-University, Langenbeckstrasse 1, 55131, Mainz, Germany.
Johannes Gutenberg University Mainz · DE

Funding

Deutsche Forschungsgemeinschaft RU 2371/1-1
6 · The paper itself

Abstract

backgroundEfficient airway management to facilitate tracheal intubation encompasses essential skills in anaesthesiologic and intensive care. The application of flexible fibreoptic intubation in patients with difficult airways has been identified as the recommended method in various international guidelines. However, providing the opportunity to adequately train residents can be challenging. Using large animals for practice during ongoing studies could help to improve this situation, but there is no recent data on fibreoptic intubation in swine available.

methodsThirty male German landrace pigs were anesthetized, instrumented and randomized into two groups. The animals were either intubated conventionally using direct laryngoscopy or a single-use flexible video-endoscope. The intervention was carried out by providers with 3 months experience in conventional intubation of pigs and a brief introduction into endoscopy. Intubation attempts were supervised and aborted, when SpO2 dropped below 93%. After three failed attempts, an experienced supervisor intervened and performed the intubation. Intubation times and attempts were recorded and analysed.

resultsFlexible fibreoptic intubation showed a significantly higher success rate in first attempt endotracheal tube placement (75% vs. 47%) with less attempts overall (1.3 ± 0.6 vs. 2.1 ± 1.3, P = 0.043). Conventional intubation was faster (42 s ± 6 s vs. 67 s ± 10s, P < 0.001), but showed a higher complication rate and more desaturation episodes during the trial.

conclusionsFlexible fibreoptic intubation in swine is feasible and appears to be a safer and more accessible method for inexperienced users to learn. This could not only improve resident training options in hospitals with animal research facilities but might also prevent airway complications and needless animal suffering.

Indexed as

PliabilityAirway ManagementAnimalsAnimal WelfareEquipment DesignFiber Optic TechnologyHumansInternship and ResidencyIntubation, IntratrachealMalePilot ProjectsProspective StudiesSwineVideo-Assisted SurgeryAirway managementAnimal safetyDifficult airwayFibreoptic intubationResident training

Identifiers

PMID32807106
PMCPMC7430093
OpenAlexW3049736405

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.