Evidence map›Paper›PMID 32802551›Full record

ArticleJournal of analytical methods in chemistry2020

Development of a Chemiluminescence Immunoassay for Quantification of 25-Hydroxyvitamin D in Human Serum.

Shuang Han, Wuxian Qiu, Junlan Zhang, Zhonghu Bai, Xiao Tong

Abstract read
In one paragraph

Article in Journal of analytical methods in chemistry, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Preparation of Luciferase-fused Peptides for Immunoassay of Amyloid Beta.Analytical sciences : the international journal of the Japan Society for Analytical Chemistry · 2021
    Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Shuang HanSchool of Biotechnology, Jiangnan University, Wuxi, China.
Wuxian QiuAffiliated Hospital of Jiangnan University, Department of Pediatrics, Wuxi, China.
Junlan ZhangSchool of Biotechnology, Jiangnan University, Wuxi, China.
Zhonghu BaiSchool of Biotechnology, Jiangnan University, Wuxi, China.ORCID https://orcid.org/0000-0003-3985-7434
Xiao TongAffiliated Hospital of Jiangnan University, Department of Pediatrics, Wuxi, China.ORCID https://orcid.org/0000-0003-0966-3321

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In this study, a chemiluminescence immunoassay (CLIA) for human serum 25-hydroxyvitamin D (25(OH)D) was established by a competition model. In serum, more than 99% of total circulating 25(OH)D binds to protein and less than 1% of 25(OH)D is in free form (Jassil et al., 2017). Before measuring concentration of 25(OH)D in serum, a releasing procedure should be conducted. A new reagent is used to release binding 25(OH)D to free form. Streptavidin (SA) was labeled to magnetic beads by a 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide/N-hydroxysuccinimide (EDC/NHS) method. Biotinylated VD was used as a competitor of 25(OH)D in samples. Anti-VD antibody (aby) was labeled to horseradish peroxidase (HRP) by EDC to react with 25(OH)D and biotinylated-VD molecules. The pretreated samples or standards were added into the reaction tube with biotin-VD and anti-VD aby-HRP, free 25(OH)D in the sample competes with biotinylated VD for binding to anti-VD aby-HRP, an SA-labeled magnetic particle is added to isolate the signal-generating complex, and the signal is inversely proportional to the 25(OH)D concentration in the sample. The method established shows good thermostability and performance. The limitation of detection (LoD) is 1.43 ng/mL. The intra-assay coefficient of variation (CV) is 3.66%-6.56%, the interassay CV is 4.19%-7.01%, and the recovery rate is 93.22%-107.99%. Cross-reactivity (CR) was remarkably low with vitamin D2, vitamin D3, 1, 25-dihydroxyvitamin D3, and 1, 25-dihydroxyvitamin D2. At the same time, the cross-reaction values with 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3 were 97% and 100%, respectively. The developed method shows good correlation with the total VD product from Roche and DiaSorin. 1096 clinical patient samples were measured with developed reagent kit in this study. 7 types of disease were involved, and the concentration of 25(OH)D is less than 30 ng/mL in 94.98% of patients.