ArticleInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences2020
Flow diverter stents with hydrophilic polymer coating for the treatment of acutely ruptured aneurysms using single antiplatelet therapy: Preliminary experience.
Article in Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers, 4 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
24 citing papers in PubMed, 4 syntheses or guidelines pooled it, 40 citations in OpenAlex.
- Single antiplatelet therapy and tirofiban bridged with surface modified flow diverters for ruptured blood blister-like aneurysms: single center experience and systematic review.Journal of neurointerventional surgery · 2026Pooled it
- Single antiplatelet regimen in flow diverter treatment of cerebral aneurysms: The drug matters. A systematic review and meta-analysis.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026Pooled it
- The safety profile of single antiplatelet therapy with flow diverters: Systematic review and meta-analysis.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026Pooled it
- Treatment of ruptured intracranial aneurysms using the novel generation of flow-diverters with surface modification: A systematic review and meta-analysis.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2024Pooled it
- Multicenter study of the safety and effectiveness of intracranial aneurysm treatment with the p64MW-HPC flow modulation device.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026Article
- Flow diverter surface modifications for aneurysm treatment: A review of the mechanisms and data behind existing technologies.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026Review
- Clinically Silent Microinfarct Incidence and Risk Factors After Treatment of Unruptured Intracranial Aneurysms with Hydrophilic Polymer-Coated Flow Diverters.Clinical neuroradiology · 2025Article
- Efficacy and safety of p48 flow diverters in the treatment of intracranial aneurysms: A systematic review and Meta-Analysis.Neuroradiology · 2025Review
- Flow diversion with hydrophilic polymer coating with prasugrel as single antiplatelet therapy in the treatment of acutely ruptured intracranial aneurysms: a multicenter case series, complication and occlusion rates.Journal of neurointerventional surgery · 2025Article
- Subacute Stent Deformities as an Underlying Reason for Vessel Stenosis after Flow Diversion with the p64 Stent: Review and Discussion of Biologic Mechanisms and Consequences.AJNR. American journal of neuroradiology · 2025Article
- Intracranial Aneurysms Treated with a Novel Coated Low-Profile Flow Diverter (p48 HPC)-A Single-Center Experience and an Illustrative Case Series.Brain sciences · 2025Article
- Tubridge flow diverter for the treatment of dissecting aneurysms in the middle cerebral artery.Frontiers in neurology · 2025Article
- Poly(2-methoxyethyl acrylate) (PMEA) improves the thromboresistance of FRED flow diverters: a thrombogenic evaluation of flow diverters with human blood under flow conditions.Journal of neurointerventional surgery · 2023Article
- Utility of flow diverters in treatment of acutely ruptured uncoilable aneurysms of the posterior circulation of the brain.Japanese journal of radiology · 2023Article
- Use of a p64 MW Flow Diverter with Hydrophilic Polymer Coating (HPC) and Prasugrel Single Antiplatelet Therapy for the Treatment of Unruptured Anterior Circulation Aneurysms: Safety Data and Short-term Occlusion Rates.Cardiovascular and interventional radiology · 2022Article
- Finnish flow diverter study: 8 years of experience in the treatment of acutely ruptured intracranial aneurysms.Journal of neurointerventional surgery · 2022Article
- Early clinical experience with the p48MW HPC and p64MW HPC flow diverters in the anterior circulation aneurysm using single anti-platelet treatment.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2022Article
- The Silk Vista Baby - The UK experience.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2022Article
- Comprehensive review of the recent advances in devices for endovascular treatment of complex brain aneurysms.The British journal of radiology · 2022Review
- pCONUS 2 and pCONUS 2-HPC for the treatment of wide-necked intracranial aneurysms: Periprocedural, 6-month, and early 2-year follow-up outcomes.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe use of flow diverter stent (FDS) has limitations in cases of subarachnoid haemorrhage caused by ruptured aneurysm, due to the need for double antiplatelet therapy and the delay in the aneurysm occluding. The p48 MW and the p64 MW (Phenox) are available with Hydrophilic Polymer Coating (HPC), that reduces the risk of thrombus formation. Purpose of this study is to evaluate the safety and efficacy of p48 and p64 MW HPC with single antiplatelet therapy for the acute treatment of ruptured aneurysm.
methodsWe retrospectively evaluated all patients treated for acutely ruptured aneurysms with a p48 MW HPC or p64 MW HPC from October 2019 to April 2020 using single antiplatelet therapy. For each patient, we considered demographic and aneurysm-related data, clinical presentation, size and location of the implanted flow diverter stent, intra- and post-procedural complications, aneurysm occlusion.
resultsSeven patients were included. The ruptured aneurysms were four saccular, two blister-like and one dissecting, six in the anterior and one in posterior circulation. No intraprocedural stent thrombosis and rebleeding was observed. In two cases the aneurysm is completely excluded, in one patient it was found only neck perfusion, in three cases there were mild reduction of the sac and in one case there was a persistent perfusion. No patients needed retreatment in this series.
conclusionIn our experience, FDS HPC appears a potential treatment option in selected cases. Our study is limited by small population and short-term follow-up. We report our preliminary data, but further investigations are necessary.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.