ReviewAnnals of translational medicine2020
Accuracy of robot-assisted versus conventional freehand pedicle screw placement in spine surgery: a systematic review and meta-analysis of randomized controlled trials.
Review in Annals of translational medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 44 papers, 3 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
44 citing papers in PubMed, 3 syntheses or guidelines pooled it, 81 citations in OpenAlex.
- Robotic-assisted versus navigation-guided spinal surgery: a meta-analysis of perioperative, clinical outcomes, and complications.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2026Pooled it
- Robot-assisted technique versus freehand technique for spine surgery: an umbrella review.Annals of medicine · 2025Pooled it
- Efficacy and safety of robotic spine surgery: systematic review and meta-analysis.Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology · 2022Pooled it
- Thoracolumbar burst fractures: robot-assisted mono-segment fixation with vertebral body grafting versus short-segment fixation - a propensity score-matched cohort study.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026Article
- Level-specific accuracy of robotic-assisted versus fluoroscopy-assisted lumbar pedicle screw placement: a retrospective comparative cohort study.Journal of robotic surgery · 2026Article
- The global landscape of robot-assisted pedicle screws: a bibliometric and thematic evolution analysis.Journal of robotic surgery · 2026Review
- Mechanized precision: the rise of robotic systems in spinal surgery.Orthopadie (Heidelberg, Germany) · 2026Review
- Robotic-assisted navigation facilitates accurate and clinically safe pedicle screw placement by a well-trained orthopaedic surgery resident when compared to an attending surgeon: a cadaveric study.Journal of robotic surgery · 2026Article
- Robot-assisted pedicle screw placement in spinal surgery: an updated systematic umbrella review and meta-meta-analysis of comparisons against freehand and navigation-guided techniques.EFORT open reviews · 2026Article
- Safety and accuracy of robot-assisted pedicle screw fixation: a randomized controlled trial.International journal of surgery (London, England) · 2025Article
- Long-term outcomes following augmented reality-assisted pedicle screw placement in spinal fusion patients.Acta neurochirurgica · 2025Article
- SurgPointTransformer: transformer-based vertebra shape completion using RGB-D imaging.Computer assisted surgery (Abingdon, England) · 2025Article
- Free-Hand Pedicle Screw Placement Using a Ball Tip Widening Technique for Small Pedicles.Clinics in orthopedic surgery · 2025Article
- A comparative study of tunnel placement accuracy in robotic-assisted versus traditional combined anterior and posterior cruciate ligament reconstruction.Journal of robotic surgery · 2025Article
- A Retrospective Cohort Study Comparing Robot-Assisted and Conventional Fluoroscopy-Guided Pedicle Screw Placement.Journal of clinical medicine · 2025Article
- Ninety-Day Complication and Revision Surgery Rates Using Navigated Robotics in Thoracolumbar Spine Surgery: A PRoGRSS Interim Analysis.International journal of spine surgery · 2025Article
- Robotic spine surgery compared with fluoroscopic-assisted surgery: advantages, disadvantages, future perspectives.Journal of robotic surgery · 2025Article
- Robot-assisted versus fluoroscopy-assisted kyphoplasty in treatment of severe osteoporotic vertebral compression fractures in the old patients: a retrospective study : Robot-assisted in treatment of severe OVCF.BMC musculoskeletal disorders · 2025Article
- Augmented Reality in Scoliosis Correction Surgery: Efficiency and Accuracy in Pedicle Screw Instrumentation.Medicina (Kaunas, Lithuania) · 2025Observational
- A relevant investigation of the degree of cement diffusion after robot-assisted percutaneous vertebroplasty.BMC musculoskeletal disorders · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This systematic review and meta-analysis investigated differences in accuracy, operation time, and radiation exposure time between robot-assisted and freehand techniques for pedicle screw insertion. Two investigators independently searched for articles on randomized controlled trials (RCTs) published from 2012 to 2019. The final meta-analysis included seven RCTs. We compared the accuracy of pedicle screw placement, operation time, and radiation exposure time between robot-assisted and conventional freehand groups. Seven RCTs included 540 patients and placement of 2,476 pedicle screws, of which 1,220 were inserted using the robot-assisted technique and 1,256 were inserted using the conventional freehand technique. The pedicle screw positions were classified using the Gertzbein and Robbins classification (grade A-E). The combined results of Grade A [odds ratio (OR) =1.68; 95% confidence intervals (CI): 0.82-3.44; P=0.16), Grade A+B (OR =1.70; 95% CI: 0.47-6.13; P=0.42), and Grade C+D+E (OR =0.59; 95% CI: 0.16-2.12; P=0.42) for the accuracy rate revealed no significant difference between the two groups. Subgroup analysis results revealed that the TiRobot-assisted technique presented a significantly improved pedicle screw insertion accuracy rate compared with that of the conventional freehand technique, based on Grade A, Grade A+B, and Grade C+D+E classifications. The SpineAssist-assisted technique presented an inferior pedicle screw insertion accuracy rate compared with that of the conventional freehand technique, based on Grade A, Grade A+B, and Grade C+D+E classifications. No difference between the Renaissance-assisted and conventional freehand techniques was noted for pedicle screw insertion accuracy rates, based on both Grade A (OR =1.58; 95% CI: 0.85-2.96; P=0.15), Grade A+B (OR =2.20; 95% CI: 0.39-12.43; P=0.37), and Grade C+D+E (OR =0.45; 95% CI: 0.08-2.56; P=0.37) classifications. Regarding operation time, robot-assisted surgery had significantly longer operation time than conventional freehand surgery. The robot-assisted group had significantly shorter radiation exposure time. Regarding the pedicle screw insertion accuracy rate, the TiRobot-assisted technique was superior, the SpineAssist-assisted technique was inferior, and Renaissance was similar to the conventional freehand technique.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.