ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2021
Low rates of serious complications but high rates of hardware removal after high tibial osteotomy with Tomofix locking plate.
Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
19 citing papers in PubMed, 41 citations in OpenAlex.
- Clinical outcomes and patient satisfaction following implant removal after open wedge high tibial osteotomy.Asia-Pacific journal of sports medicine, arthroscopy, rehabilitation and technology · 2026Article
- Risk factors for surgical site infection requiring reoperation after osteotomy around the knee: a multicenter retrospective study.BMC musculoskeletal disorders · 2026Observational
- Clinical and radiographic outcomes of double-triangle locking compression plate (DT-LCP) versus T-shaped locking compression plate (T-LCP) in medial open-wedge high tibial osteotomy: a follow-up study of over 5 years.Journal of orthopaedic surgery and research · 2026Article
- High tibial osteotomy with virtual planning and patient specific instrumentation: a narrative review.Annals of joint · 2026Review
- Lateral closing wedge high tibial osteotomy procedure for the treatment of medial knee osteoarthritis: eleven years mean follow up analysis.International orthopaedics · 2025Article
- [Research progress in biomechanics of different fixation methods for medial opening-wedge high tibial osteotomy].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2025Review
- Experience of High Tibial Osteotomy for Patients with Rheumatoid Arthritis Treated with Recent Medication: A Case Series.Journal of clinical medicine · 2025Article
- Percutaneous removal of hardware after orthopedic surgery: Is it safe? and What are patients saying?European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2024Article
- Are TomoFix Locking Plates Really Anatomical for Indian Population?Indian journal of orthopaedics · 2024Article
- Effect of hardware removal and second-look arthroscopy after open-wedge high tibial osteotomy.Archives of orthopaedic and trauma surgery · 2024Article
- A systematic approach to managing complications after proximal tibial osteotomies of the knee.Journal of experimental orthopaedics · 2023Review
- Osteotomy around the painful degenerative varus knee: a 2022 ESSKA formal consensus.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2023Article
- Removal Rate of the TomofixRevista brasileira de ortopedia · 2023Article
- Research on the Influence of the Allogeneic Bone Graft in Postoperative Recovery After MOWHTO: A Retrospective Study.Therapeutics and clinical risk management · 2023Article
- Complications after high tibial osteotomy and distal femoral osteotomy are associated with increasing medical comorbidities and tobacco use.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2022Article
- Vancomycin-soaked femoral head allograft in opening wedge high tibia osteotomy enables earlier postoperative recovery and reduces infection rates compared to allogenic bone chips.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2022Article
- Comparison of Anatomical Conformity between TomoFix Anatomical Plate and TomoFix Conventional Plate in Open-Wedge High Tibial Osteotomy.Medicina (Kaunas, Lithuania) · 2022Article
- Does a lateral tibial plateau fracture (Takeuchi type III) occuring during opening wedge high tibial osteotomy induce a higher revision rate to total knee arthroplasty.Acta bio-medica : Atenei Parmensis · 2022Article
- Preoperative planning by osteotomy master software helps to improve the accuracy of target limb alignment in high tibial osteotomy.Journal of orthopaedic surgery and research · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe purpose of this study was to analyse adverse events encountered in medial opening wedge high tibial osteotomy (MOWHTO) utilizing contemporary surgical techniques with the Tomofix locking plate (DePuy Synthes, Raynham, MA, USA) and categorize them by their severity and need for further medical/surgical management. It was hypothesized that there would be low rates of serious complications after medial opening wedge high tibial osteotomy utilizing an internal locking plate fixator.
methodsThis study included 169 consecutive patients (200 knees) who underwent MOWHTO with a Tomofix locking plate at a single center, completing a minimum 2-year follow-up. Types of intra- and post-operative adverse events were retrospectively identified by an independent observer and categorized by their severity and further need of management. Additional surgery due to elective hardware removal was not included in the adverse event classification.
resultsThere were in total 58 (29%) adverse events, the majority (13.5%) of which required no additional treatment (class 1). Class 1 events included lateral cortex hinge fractures that were observed in 8.5% (17 knees) and delayed wound healing 2% (4/200). Adverse events requiring additional or extended nonoperative management (class 2) were 9%. These included post-operative stiffness in 1% (2/200), low grade infection in 1.5% (3/200), delayed union in 5.4% (11/200), deep vein thrombosis 0.5% (1/200). One hundred and four knees (52%) underwent elective hardware removal. Serious adverse events requiring unplanned additional or revision surgery and/or long-term medical care (class 3) were the least reported (6.5%). Aseptic non-union was reported in 2.5%, deep infection requiring revision in 2% and limited hardware failure 1%.
conclusionA low rate of serious complications (6.5%) requiring unplanned additional surgery (class 3) was found. The overall rate of complications following MOWHTO with Tomofix locking plate was 29% and the majority (13.5%) required no additional treatment (class 1). Lateral hinge fractures were the most common complication (8.5%) and these were associated with corrections over 12 mm. However, 52% knees required a further operation for elective hardware removal. LEVEL OF EVIDENCE: Level IV, prospective study without control group.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.