Evidence map›Paper›PMID 32788693›Full record

ArticleScientific reports2020

Polyaniline/Ag nanoparticles/graphene oxide nanocomposite fluorescent sensor for recognition of chromium (VI) ions.

Shaker Ebrahim, Azza Shokry, M M A Khalil, Hesham Ibrahim, Moataz Soliman

Abstract read
In one paragraph

Article in Scientific reports, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Detecting CrAdvanced materials (Deerfield Beach, Fla.) · 2025
    Article
  5. Sensing of heavy metal PbScientific reports · 2024
    Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Shaker EbrahimDepartment of Materials Science, Institute of Graduate Studies and Research, Alexandria University, P.O. Box 832, Alexandria, Egypt.
Azza ShokryDepartment of Environmental Studies, Institute of Graduate Studies and Research, Alexandria University, P.O. Box 832, Alexandria, Egypt. azzashokry@alexu.edu.eg.
M M A KhalilDepartment of Nanotechnology and Composite Materials, Institute of New Materials and Advanced Technology, City of Scientific Research and Technological Applications (SRTA- City), New Borg El Arab City, P.O. Box 21934, Alexandria, Egypt.
Hesham IbrahimDepartment of Environmental Studies, Institute of Graduate Studies and Research, Alexandria University, P.O. Box 832, Alexandria, Egypt.
Moataz SolimanDepartment of Materials Science, Institute of Graduate Studies and Research, Alexandria University, P.O. Box 832, Alexandria, Egypt.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Selective determination of toxic hexavalent chromium (Cr(VI)) is a stringent important due to its huge negative impact on the health and environment. Recently, the high sensitivity, rapidness, and cost-effectiveness of the fluorescent sensors for Cr(VI) have been developed. A fluorescent nanocomposite (NC) has been synthesized based on doped polyaniline (PANI), 2-acrylamido-2-methylpropanesulfonic acid (AMPSA) capped Ag nanoparticles (NPs) and graphene oxide (GO) quantum dots (QDs) via in situ reaction for highly selective sensing of Cr(VI) ions based on the luminescent quenching in the range from 0.01 to 7.5 mg/L. This NC showed an emission peak at 348 nm with a linear range from 0.01 to 0.05 mg/L and the low limit of detection (LOD) was 0.0065 mg/L (~ 6 µg/L). PANI/Ag (AMPSA) GO QDs NC displayed high selectivity for Cr(VI) over other common metal ions. Notably, the PANI/Ag (AMPSA) GO QDs NC can be used for distinguishing Cr(VI) and Cr(III) in solutions. The sensitive determination of Cr(VI) in real surface water samples was also confirmed and demonstrated recoveries in the range 95.3-99.2%. This NC will emerge as a new class of fluorescence materials that could be suitable for practical applications.

Identifiers

PMID32788693
PMCPMC7423961

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked