ArticleDiagnostics (Basel, Switzerland)2020
Design, Development, and Multi-Characterization of an Integrated Clinical Transrectal Ultrasound and Photoacoustic Device for Human Prostate Imaging.
Article in Diagnostics (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07784179 (Ultrasound and Photoacoustic Imaging of Hydrocephalus), which is not on this map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Ultrasound and Photoacoustic Imaging of Hydrocephalus
Who cites it
11 citing papers in PubMed.
- Development of a Dual Photoacoustic-Ultrasound Imaging System: Current Status and Future Perspectives.Sensors (Basel, Switzerland) · 2026Review
- Clinical translation of photoacoustic imaging using exogenous molecular contrast agents [Invited].Biomedical optics express · 2025Review
- Advanced Ultrasound Energy Transfer Technologies using Metamaterial Structures.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024Review
- Flexible, biodegradable ultrasonic wireless electrotherapy device based on highly self-aligned piezoelectric biofilms.Science advances · 2024Article
- Dual-modal Photoacoustic and Ultrasound Imaging: from preclinical to clinical applications.Frontiers in photonics · 2024Article
- Characterization of adnexal lesions using photoacoustic imaging to improve sonographic O-RADS risk assessment.Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology · 2023Article
- A Coregistered Ultrasound and Photoacoustic Imaging Protocol for the Transvaginal Imaging of Ovarian Lesions.Journal of visualized experiments : JoVE · 2023Article
- A Transparent Ultrasound Array for Real-Time Optical, Ultrasound, and Photoacoustic Imaging.BME frontiers · 2022Article
- Clinical photoacoustic/ultrasound dual-modal imaging: Current status and future trends.Frontiers in physiology · 2022Review
- Modeling combined ultrasound and photoacoustic imaging: Simulations aiding device development and artificial intelligence.Photoacoustics · 2021Article
- Review of consensus test methods in medical imaging and current practices in photoacoustic image quality assessment.Journal of biomedical optics · 2021Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
The standard diagnostic procedure for prostate cancer (PCa) is transrectal ultrasound (TRUS)-guided needle biopsy. However, due to the low sensitivity of TRUS to cancerous tissue in the prostate, small yet clinically significant tumors can be missed. Magnetic resonance imaging (MRI) with TRUS fusion biopsy has recently been introduced as a way to improve the identification of clinically significant PCa in men. However, the spatial errors in coregistering the preprocedural MRI with the real-time TRUS causes false negatives. A real-time and intraprocedural imaging modality that can sensitively detect PCa tumors and, more importantly, differentiate aggressive from nonaggressive tumors could largely improve the guidance of biopsy sampling to improve diagnostic accuracy and patient risk stratification. In this work, we seek to fill this long-standing gap in clinical diagnosis of PCa via the development of a dual-modality imaging device that integrates the emerging photoacoustic imaging (PAI) technique with the established TRUS for improved guidance of PCa needle biopsy. Unlike previously published studies on the integration of TRUS with PAI capabilities, this work introduces a novel approach for integrating a focused light delivery mechanism with a clinical-grade commercial TRUS probe, while assuring much-needed ease of operation in the transrectal space. We further present the clinical potential of our device by (i) performing rigorous characterization studies, (ii) examining the acoustic and optical safety parameters for human prostate imaging, and (iii) demonstrating the structural and functional imaging capabilities using deep-tissue-mimicking phantoms. Our TRUSPA experimental studies demonstrated a field-of-view in the range of 130 to 150 degrees and spatial resolutions in the range of 300 μm to 400 μm at a soft tissue imaging depth of 5 cm.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.