Evidence map›Paper›PMID 32784512›Full record

ArticleSensors (Basel, Switzerland)2020

Polarizer-Free AOTF-Based SWIR Hyperspectral Imaging for Biomedical Applications.

Vladislav Batshev, Alexander Machikhin, Grigoriy Martynov, Vitold Pozhar, Sergey Boritko, Milana Sharikova, Vladimir Lomonov, Alexander Vinogradov

Abstract readLetter
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Review
  4. Article
  5. Review
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Vladislav BatshevScientific and Technological Center of Unique Instrumentation Russian Academy of Sciences, Butlerova Str. 15, Moscow 117342, Russia.
Alexander MachikhinScientific and Technological Center of Unique Instrumentation Russian Academy of Sciences, Butlerova Str. 15, Moscow 117342, Russia.
Grigoriy MartynovScientific and Technological Center of Unique Instrumentation Russian Academy of Sciences, Butlerova Str. 15, Moscow 117342, Russia.ORCID 0000-0003-2618-9457
Vitold PozharScientific and Technological Center of Unique Instrumentation Russian Academy of Sciences, Butlerova Str. 15, Moscow 117342, Russia.
Sergey BoritkoScientific and Technological Center of Unique Instrumentation Russian Academy of Sciences, Butlerova Str. 15, Moscow 117342, Russia.
Milana SharikovaScientific and Technological Center of Unique Instrumentation Russian Academy of Sciences, Butlerova Str. 15, Moscow 117342, Russia.
Vladimir LomonovFederal Scientific Research Center "Crystallography and Photonics", Russian Academy of Sciences, Moscow 119333, Russia.
Alexander VinogradovFederal Scientific Research Center "Crystallography and Photonics", Russian Academy of Sciences, Moscow 119333, Russia.

Funding

Federal State Task Program of the Federal Scientific Research Center "Crystallography and Photonics" Federal State Task ProgramRussian Foundation for Basic Research 18-29-20095
6 · The paper itself

Abstract

Optical biomedical imaging in short wave infrared (SWIR) range within 0.9-1.7 μm is a rapidly developing technique. For this reason, there is an increasing interest in cost-effective and robust hardware for hyperspectral imaging data acquisition in this range. Tunable-filter-based solutions are of particular interest as they provide image processing flexibility and effectiveness in terms of collected data volume. Acousto-optical tunable filters (AOTFs) provide a unique set of features necessary for high-quality SWIR hyperspectral imaging. In this paper, we discuss a polarizer-free configuration of an imaging AOTF that provides a compact and easy-to-integrate design of the whole imager. We have carried out image quality analysis of this system, assembled it and validated its efficiency through multiple experiments. The developed system can be helpful in many hyperspectral applications including biomedical analyses.

Indexed as

Biomedical TechnologyHyperspectral ImagingImage Processing, Computer-AssistedDiagnostic ImagingRadio Wavesacousto-optical tunable filterBragg diffractionhyperspectral imagingshort wave infrared rangespectral imaging

Identifiers

PMID32784512
PMCPMC7472359

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.