ArticlePhysiological measurement2020
An open-source automated algorithm for removal of noisy beats for accurate impedance cardiogram analysis.
Article in Physiological measurement, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 14 citations in OpenAlex.
- [Research on motion impedance cardiography de-noising method based on two-step spectral ensemble empirical mode decomposition and canonical correlation analysis].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2024Article
- Exaggerated Peripheral and Systemic Vasoconstriction During Trauma Recall in Posttraumatic Stress Disorder: A Co-Twin Control Study.Biological psychiatry · 2024Article
- Impedance cardiogram based exploration of cardiac mechanisms in post-traumatic stress disorder during trauma recall.Psychophysiology · 2024Article
- Robust Arm Impedocardiography Signal Quality Enhancement Using Recursive Signal Averaging and Multi-Stage Wavelet Denoising Methods for Long-Term Cardiac Contractility Monitoring Armbands.Sensors (Basel, Switzerland) · 2023Article
- Association between PTSD and Impedance Cardiogram-based contractility metrics during trauma recall: A controlled twin study.Psychophysiology · 2023Article
- An Effective Method of Detecting Characteristic Points of Impedance Cardiogram Verified in the Clinical Pilot Study.Sensors (Basel, Switzerland) · 2022Article
- Data-driven approach for automatic detection of aortic valve opening: B point detection from impedance cardiogram.Psychophysiology · 2022Article
- Validation of a new impedance cardiography analysis algorithm for clinical classification of stress states.Psychophysiology · 2022Article
- Pulse arrival time as a surrogate of blood pressure.Scientific reports · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 2 institutions in 1 country.
Funding
Abstract
objectiveThe impedance cardiogram (ICG) is a non-invasive sensing modality for assessing the mechanical aspects of cardiac function, but is sensitive to artifacts from respiration, speaking, motion, and electrode displacement. Electrocardiogram (ECG)-synchronized ensemble averaging of ICG (conventional ensemble averaging method) partially mitigates these disturbances, as artifacts from intra-subject variability (ISVar) of ICG morphology and event latency remain. This paper describes an automated algorithm for removing noisy beats for improved artifact suppression in ensemble-averaged (EA) ICG beats. APPROACH: Synchronized ECG and ICG signals from 144 male subjects at rest in different psychological conditions were recorded. A 'three-stage EA ICG beat' was formed by passing 60-seconds non-overlapping ECG-synchronized ICG signals through three filtering stages. The amplitude filtering stage removed spikes/noisy beats with amplitudes outside of normal physiological ranges. Cross-correlation was applied to remove noisy beats in coarse and fine filtering stages. The accuracy of the algorithm-detected artifacts was measured with expert-identified artifacts. Agreement between the expert and the algorithm was assessed using intraclass correlation coefficients (ICC) and Bland-Altman plots. The ISVar of the cardiac parameters was evaluated to quantify improvement in these estimates provided by the proposed method. MAIN
resultsThe proposed algorithm yielded an accuracy of 96.3% and high inter-rater reliability (ICC > 0.997). Bland-Altman plots showed consistently accurate results across values. The ISVar of the cardiac parameters derived using the proposed method was significantly lower than those derived via conventional ensemble averaging method (p < 0.0001). Enhancement in resolution of fiducial points and smoothing of higher-order time derivatives of the EA ICG beats were observed. SIGNIFICANCE: The proposed algorithm provides a robust framework for removal of noisy beats and accurate estimation of ICG-based parameters. Importantly, the methodology reduced the ISVar of cardiac parameters. An open-source toolbox has been provided to enable other researchers to readily reproduce and improve upon this work.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.