Artifacts annotations in anesthesia blood pressure data by man and machine.

Wietze Pasma, Esther M Wesselink, Stef van Buuren, Jurgen C de Graaff, Wilton A van Klei

Abstract read
In one paragraph

Article in Journal of clinical monitoring and computing, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. What is new in hemodynamic monitoring and management?Journal of clinical monitoring and computing · 2022
    Review
  8. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors.

Wietze PasmaDepartment of Anesthesiology, University Medical Center Utrecht, Utrecht University, Heidelberglaan, 100 3584XC, Utrecht, The Netherlands. w.pasma@umcutrecht.nl.ORCID http://orcid.org/0000-0003-1972-8731
Esther M WesselinkDepartment of Anesthesiology, University Medical Center Utrecht, Utrecht University, Heidelberglaan, 100 3584XC, Utrecht, The Netherlands.ORCID http://orcid.org/0000-0003-3371-2680
Stef van BuurenNetherlands Organization for Applied Scientific Research and Department of Methodology & Statistics, Faculty of Social and Behavioural Sciences, University of Utrecht, Utrecht, The Netherlands.ORCID http://orcid.org/0000-0003-1098-2119
Jurgen C de GraaffDepartment of Anesthesiology, Erasmus MC - Sophia Children's Hospital, Rotterdam, The Netherlands.ORCID http://orcid.org/0000-0002-2168-7900
Wilton A van KleiDepartment of Anesthesiology, University Medical Center Utrecht, Utrecht University, Heidelberglaan, 100 3584XC, Utrecht, The Netherlands.ORCID http://orcid.org/0000-0003-2665-1672

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Physiologic data from anesthesia monitors are automatically captured. Yet erroneous data are stored in the process as well. While this is not interfering with clinical care, research can be affected. Researchers should find ways to remove artifacts. The aim of the present study was to compare different artifact annotation strategies, and to assess if a machine learning algorithm is able to accept or reject individual data points. Non-cardiac procedures requiring invasive blood pressure monitoring were eligible. Two trained research assistants observed procedures live for artifacts. The same procedures were also retrospectively annotated for artifacts by a different person. We compared the different ways of artifact identifications and modelled artifacts with three different learning algorithms (lasso restrictive logistic regression, neural network and support vector machine). In 88 surgical procedures including 5711 blood pressure data points, the live observed incidence of artifacts was 2.1% and the retrospective incidence was 2.2%. Comparing retrospective with live annotation revealed a sensitivity of 0.32 and specificity of 0.98. The performance of the learning algorithms which we applied ranged from poor (kappa 0.053) to moderate (kappa 0.651). Manual identification of artifacts yielded different incidences in different situations, which were not comparable. Artifact detection in physiologic data collected during anesthesia could be automated, but the performance of the learning algorithms in the present study remained moderate. Future research should focus on optimization and finding ways to apply them with minimal manual work. The present study underlines the importance of an explicit definition for artifacts in database research.

Indexed as

AnesthesiaArtifactsAlgorithmsBlood PressureHumansMaleRetrospective StudiesVital SignsAnesthesiaArtifactsMachine learningPhysiologic data

Identifiers

PMID32783094
PMCPMC7943498

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.