Evidence map›Paper›PMID 32781400›Full record

ArticleUltramicroscopy2020

Analyzing contrast in cryo-transmission electron microscopy: Comparison of electrostatic Zach phase plates and hole-free phase plates.

Martin Obermair, Simon Hettler, Chyongere Hsieh, Manuel Dries, Michael Marko, Dagmar Gerthsen

Open access · hybridAbstract readComparative Study
In one paragraph

Article in Ultramicroscopy, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.4field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 5 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 3 countries.

Martin ObermairKarlsruher Institut für Technologie (KIT), Laboratorium für Elektronenmikroskopie (LEM), Engesserstraße 7, 76131 Karlsruhe, Germany. Electronic address: martin.obermair@kit.edu.
Simon HettlerUniversidad de Zaragoza, Instituto de Nanociencia de Aragón (INA), Laboratorio de Microscopías Avanzadas (LMA), C/ Mariano Esquillor s/n, Edificio I+D - Campus Río Ebro, 50018 Zaragoza, Spain.
Chyongere HsiehNew York State Department of Health (NYSDOH), Wadsworth Center, Empire State Plaza, P.O. Box 509, Albany, NY 12201-0509, United States.
Manuel DriesKarlsruher Institut für Technologie (KIT), Laboratorium für Elektronenmikroskopie (LEM), Engesserstraße 7, 76131 Karlsruhe, Germany.
Michael MarkoNew York State Department of Health (NYSDOH), Wadsworth Center, Empire State Plaza, P.O. Box 509, Albany, NY 12201-0509, United States; College of Nanoscale Science and Engineering, SUNY Polytechnic Institute, 257 Fuller Road, Albany, NY 12203, United States.
Dagmar GerthsenKarlsruher Institut für Technologie (KIT), Laboratorium für Elektronenmikroskopie (LEM), Engesserstraße 7, 76131 Karlsruhe, Germany.
Karlsruhe Institute of Technology · DENew York State Department of Health · USUniversidad de Zaragoza · ESWadsworth Center · US

Funding

National Research Mentoring Network for a Diverse Biomedical WorkforceU54GM119023 · NIGMS · BOSTON COLLEGE · PI OFILI, ELIZABETH O., OKUYEMI, KOLAWOLE S · 2015 to 2018
$15.3M
TECHNOLOGY DEVELOPMENT FOR CRYO-EM APPLICATIONSR35GM118023 · NIGMS · WADSWORTH CENTER · PI MARKO, MICHAEL · 2016 to 2020
$3.2M
NIGMS NIH HHS R35 GM118023NIGMS NIH HHS U54 GM119023
6 · The paper itself

Abstract

Phase plates (PPs) are beneficial devices to improve the phase contrast of life-science objects in cryo-transmission electron microscopy (TEM). The development of the hole-free (HF) PP, which consists of a thin carbon film, has led to impressive results due to its ease in fabrication, implementation and application. However, the phase shift of the HFPP can be controlled only indirectly. The electrostatic Zach PP uses a strongly localized and adjustable electrostatic potential to generate well-defined and variable phase shifts between scattered and unscattered electrons. However, artifacts in phase-contrast TEM images are induced by the presence of the PP rod in the diffraction plane. We present a detailed analysis and comparison of the contrast-enhancing capabilities of both PP types and their emerging artifacts. For this purpose, cryo-TEM images of a standard T4-bacteriophage test sample were acquired with both PP types. Simulated images reproduce the experimental images well and substantially contribute to the understanding of contrast formation. An electrostatic Zach PP was used in this work to acquire cryo-electron tomograms with enhanced contrast, which are of similar quality as tomograms obtained by HFPP TEM.

Indexed as

ArtifactsBacteriophage T4Computer SimulationCryoelectron MicroscopyElectronsHistocytological Preparation TechniquesMicroscopy, Electron, TransmissionMicroscopy, Phase-ContrastBiological specimenCryo-electron tomography (cryo-ET)Cryo-transmission electron microscopy (TEM)Phase contrastPhase plateThin film

Identifiers

PMID32781400
PMCPMC8848455
OpenAlexW3046015060

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.