Evidence map›Paper›PMID 32780305›Full record

SynthesisSpine deformity2021

A systematic review of metal ion concentrations following instrumented spinal fusion.

Omar Siddiqi, Jennifer C Urquhart, Parham Rasoulinejad

Abstract readSystematic Review
PubMed Publisher
In one paragraph

Synthesis in Spine deformity, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Observational
  2. Review
  3. Article
  4. Review
  5. Outcomes following instrumentation removal after posterior corrective fixation in adolescent idiopathic scoliosis.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2025
    Article
  6. Review
  7. Serum metal ion levels following spinal deformity surgery: a case-control study of 182 individuals.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2022
    Article
  8. Article
  9. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Omar SiddiqiRCSI Bahrain, Busaiteen, Muharraq, Bahrain.ORCID 0000-0003-3436-9693
Jennifer C UrquhartDepartment of Surgery, London Health Sciences Center, E1-311, 800 Commissioners Road, East, London, ON, N6A 4G5, Canada.ORCID 0000-0002-9393-814X
Parham RasoulinejadDepartment of Surgery, London Health Sciences Center, E1-311, 800 Commissioners Road, East, London, ON, N6A 4G5, Canada. Parham.Rasoulinejad@lhsc.on.ca.ORCID 0000-0002-3031-2633

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeMetallic spinal implants undergo wear and corrosion which liberates ionic or particulate metal debris. The purpose of this study was to identify and review studies that report the concentration of metal ions following multi-level spinal fusion and to evaluate the impact on clinical outcomes.

methodsDatabases (PubMed, EBSCO MEDLINE) were searched up to August 2019 for studies in English-language assessing metal ion levels [chromium (Cr), titanium (Ti), nickel (Ni)] in whole blood, serum, or plasma after spinal fusion using a specific search string. Study, patient, and implant characteristics, method of analysis, metal ion concentration, as well as clinical and radiographic results was extracted.

resultsThe systematic search yielded 18 studies encompassing 653 patients. 9 studies reported Ti ions, eight reported Cr, and six reported Ni. Ti levels were elevated compared to controls/reference range/preoperative baseline in seven studies with the other two reporting no difference. Cr levels were elevated compared to controls/reference range in seven studies with one reporting no difference. Ni levels showed no difference from controls/reference range in four studies with one reporting above normal and another elevated compared to controls. Radiographic evidence of corrosion, implant failure, pseudarthrosis, revision surgery and adverse reaction reporting was highly variable.

conclusionMetal ions are elevated after instrumented spinal fusion; notably Cr levels from stainless steel implants and Ti from titanium implants. The association between clinical and radiographic outcomes remain uncertain but is concerning. Further research with standardized reporting over longer follow-up periods is indicated to evaluate the clinical impact and minimizing risk.

Indexed as

Spinal DiseasesSpinal FusionChromiumHumansIonsMetalsChromiumIonsMetalsMetal ionScoliosisSpinal fusionSpinal implantSpinal instrumentation

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.