Evidence map›Paper›PMID 32775410›Full record

ArticleBioMed research international2020

The Effects of Titanium Surfaces Modified with an Antimicrobial Peptide GL13K by Silanization on Polarization, Anti-Inflammatory, and Proinflammatory Properties of Macrophages.

Xuxi Chen, Lin Zhou, Dong Wu, Wenxiu Huang, Yanjun Lin, Bowei Zhou, Jiang Chen

Open access · hybridAbstract read
In one paragraph

Article in BioMed research international, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
0.8field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 24 citations in OpenAlex.

  1. Review
  2. Review
  3. Review
  4. Article
  5. Review
  6. Bone response in vivo of Ti-45Zr alloy as dental implant material.Journal of materials science. Materials in medicine · 2022
    Article
  7. Review
  8. Review
  9. Review
  10. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Xuxi ChenFujian Key Laboratory of Oral Diseases, School and Hospital of Stomatology, Fujian Medical University, China.ORCID https://orcid.org/0000-0001-9980-097X
Lin ZhouFujian Provincial Engineering Research Center of Oral Biomaterial, School and Hospital of Stomatology, Fujian Medical University, China.
Dong WuStomatological Key Lab of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, China.
Wenxiu HuangResearch Center of Dental and Craniofacial Implant, School and Hospital of Stomatology, Fujian Medical University, China.ORCID https://orcid.org/0000-0003-2939-5846
Yanjun LinInstitute of Stomatology, School and Hospital of Stomatology, Fujian Medical University, China.
Bowei ZhouDepartment of Oral Implantology, School and Hospital of Stomatology, Fujian Medical University, China.
Jiang ChenInstitute of Stomatology & Research Center of Dental and Craniofacial Implant, School and Hospital of Stomatology, Fujian Medical University, China.ORCID https://orcid.org/0000-0002-2177-7914
Fujian Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The polarization of macrophages and its anti-inflammatory and proinflammatory properties play a significant role in host response after implant placement to determine the outcome of osseointegration and long-term survival. In the previous study, we immobilized an antimicrobial peptide, GL13K, onto titanium surfaces to provide immune regulation property. In the herein presented study, we aimed at investigating whether GL13K immobilized titanium surface could improve osteogenesis and reduce the inflammatory reaction around the biomaterials by altering macrophage response. We evaluated the cell proliferation of the different phenotypes of macrophages seeded in GL13K-coated titanium surface, which indicated an inhibition of M1 macrophages and a good cytocompatibility to M2 macrophages. Then, we measured the inflammatory and anti-inflammatory activity of the M1 and M2 macrophages seeded on the GL13K-coated titanium surfaces. The results of the enzyme-linked immunosorbent assay and quantitative reverse transcription-polymerase chain reaction showed that the group with the GL13K modified surface had a downregulation in the expression level of the tumor necrosis factor-

Indexed as

Coated Materials, BiocompatibleOligopeptidesTitaniumAnimalsBisphenol A-Glycidyl MethacrylateInflammationMacrophagesMiceRAW 264.7 CellsBisphenol A-Glycidyl MethacrylateCoated Materials, BiocompatibleGL13KOligopeptidesSilar (3M)Titanium

Identifiers

PMID32775410
PMCPMC7396038
OpenAlexW3044931624

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.