ArticleJournal of orthopaedic translation2020
Higher stability and more predictive fixation with the Femoral Neck System versus Hansson Pins in femoral neck fractures Pauwels II.
Article in Journal of orthopaedic translation, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 63 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
63 citing papers in PubMed, 2 syntheses or guidelines pooled it, 91 citations in OpenAlex.
- Pooled it
- Comparison of femoral neck system versus cannulated screws for treatment of femoral neck fractures: a systematic review and meta-analysis.BMC musculoskeletal disorders · 2023Pooled it
- Clinical efficacy of personalized 3D-printed modular navigation templates in assisting Femoral Neck System implantation for femoral neck fractures in young and middle-aged adults.BMC musculoskeletal disorders · 2025Trial
- Comparison of dynamic hip screw with anti-rotation screw and femoral neck system internal fixation for the treatment of garden II-IV type femoral neck fractures.Technology and health care : official journal of the European Society for Engineering and Medicine · 2024Trial
- The Utility of Virtual Reality in Orthopedic Surgical Training.Journal of surgical educationTrial
- Exploring the Effectiveness of "Four-Point" Configuration Cannulated Compression Screw Implantation Protocol for the Fixation of Pauwels Type III Femoral Neck Fractures in Adults.Orthopaedic surgery · 2026Article
- Enhanced Stability in an Unstable Femoral Neck Fracture Using the Femoral Neck System with Two Additional Cannulated Cancellous Screws: A Case Report.Journal of orthopaedic case reports · 2026Article
- Does FNS outperform CCS in Pauwel's type III fracture fixation: a combined experimental and numerical study.Medical & biological engineering & computing · 2026Article
- Clinical and radiographic outcomes of multiple cannulated cancellous screw fixation versus the femoral neck system for femoral neck fractures in the elderly: a multicenter retrospective comparative study.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2026Article
- Early results of the femoral neck system in fixation of femoral neck fractures.Singapore medical journal · 2026Article
- Femoral Neck System Versus Total Hip Arthroplasty in the Treatment of Pauwels Type III Unstable Femoral Neck Fractures in Patients Aged 60-70 Years: A Comparative Analysis of Clinical Efficacy and Hip Function.Orthopaedic surgery · 2026Article
- Finite element analysis of the influence of femoral neck system implantation angle on biomechanical stability in femoral neck fractures: a mechanistic exploration.BMC musculoskeletal disorders · 2026Article
- Comparison of clinical efficacy and psychological outcomes of femoral neck system combined with rhBMP-2 for young adult femoral neck fractures.Frontiers in surgery · 2026Article
- Clinical application of the femoral neck system in the treatment of femoral neck fractures.Frontiers in surgery · 2026Article
- Comparative study of femoral neck shortening following two types of internal fixation in young and middle-aged patients with displaced femoral neck fractures.Frontiers in surgery · 2026Article
- FNS as a more satisfactory surgical option for young and middle-aged patients with femoral neck fractures.Scientific reports · 2025Article
- Failure of the Femoral Neck System in a Young Patient: A Case Report.Journal of orthopaedic case reports · 2025Article
- Biomechanical evaluation of novel construct for stabilizing subcapital femoral neck fractures: a synthetic bone model.BMC musculoskeletal disorders · 2025Article
- An innovative self-stabilised 3D-printed artificial vertebral body designed for clinical application and comparison with the conventional implants.Journal of orthopaedic translation · 2025Article
- Comparative study of rhBMP-2 assisted femoral neck system and cannulated screws in femoral neck fractures: clinical efficacy and psychological status.Scientific reports · 2025Article
3 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 4 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesTo evaluate the biomechanical performance of the Femoral Neck System (FNS) versus the Hansson Pin System (Hansson Pins) with two parallel pins in a Pauwels II femoral neck fracture model with posterior comminution.
methodsForty-degree Pauwels II femoral neck fractures AO 31-B2.1 with 15° posterior wedge were simulated in fourteen paired fresh-frozen human femora, followed by instrumentation with either FNS or Hansson Pins in pair-matched fashion. Implant positioning was quantified by measuring shortest implant distances to inferior cortex (DI) and posterior cortex (DP) on anteroposterior and axial X-rays, respectively. Biomechanical testing was performed in 20° adduction and 10° flexion with simulated iliopsoas muscle tension. Progressively increasing cyclic loading was applied until construct failure. Interfragmentary femoral head-to-shaft movements were measured with optical motion tracking.
resultsCycles to 10° varus deformation were significantly higher for FNS (23007 ± 5496) versus Hansson Pins (17289 ± 4686), P = 0.027. Cycles to 10° femoral head dorsal tilting (FNS: 12765 ± 3425; Hansson Pins: 13357 ± 6104) and cycles to 10° rotation around the femoral neck axis (FNS: 24453 ± 5073; Hansson Pins: 20185 ± 11065) were comparable between the implants, P ≥ 0.314. For Hansson Pins, the outcomes for varus deformation and dorsal tilting correlated significantly with DI and DP, respectively (P ≤ 0.047), whereas these correlations were not significant for FNS (P ≥ 0.310).
conclusionsFrom a biomechanical perspective, by providing superior resistance against varus deformation and performing in a less sensitive way to variations in implant placement, the angular stable Femoral Neck System can be considered as a valid alternative to the Hansson Pin System for the treatment of Pauwels II femoral neck fractures. LEVEL OF EVIDENCE: therapeutic, Level V. THE TRANSLATIONAL POTENTIAL OF THIS ARTICLE: The translational potential of this article is to compare the performance of the FNS with Hansson Pins in a AO 31-B2.1 fracture model featuring a 15 posterior wedge to show the implants behavior concerning the dorsal tilting tendency.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.