ArticleIEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division2019
MR-Conditional SMA-Based Origami Joint.
Article in IEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Origami-inspired reprogrammable microactuator system.Microsystems & nanoengineering · 2025Article
- 4D Multiscale Origami Soft Robots: A Review.Polymers · 2022Review
- Revealing the Dynamic Characteristics of Composite Material-Based Miura-Origami Tube.Materials (Basel, Switzerland) · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
Foldable origami structures have been implemented into robotics as a way of compacting joints and circuitry into smaller structures. This technique is especially useful in minimally invasive surgical instruments, where the goal is to create slimline devices that can be inserted through small incisions. Origami also has the potential to cut costs by reducing the amount of material required for assembly. Origami devices are especially suitable for MRI-guided procedures, where instruments must be nonmagnetic because origami is more suitable for flexible, non-metallic materials. MR conditional surgical instruments enable intraoperative MRI procedures that provide superior imaging capabilities to physicians to allow for safer procedures. This work presents an MR conditional joint developed using origami techniques that reduces costs by eliminating assembly of various components and has potential applications in endoscopy. The joint is a compliant rolling-contact element that employs curved-folding origami techniques. A chain of these joints can be constructed from a single sheet of material, eliminating assembly of numerous materials to produce a final product, which is specifically advantageous for constructing low-cost, disposable surgical devices. The prototype contains a degree of bending of ±9 degrees per joint, a response time of less than 4 seconds and an actuation force of 0.5 N using a 1.25 A current. The MRI results showed a minimal artifact of less than 1 mm measured from the boundary of the joint chain and a SNR reduction of less than 10%.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.