Evidence map›Paper›PMID 32774079›Full record

ArticleIEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division2019

MR-Conditional SMA-Based Origami Joint.

Austin J Taylor, Trent Slutzky, Leah Feuerman, Hongliang Ren, Junichi Tokuda, Kent Nilsson, Zion Tsz Ho Tse

Abstract read
In one paragraph

Article in IEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Origami-inspired reprogrammable microactuator system.Microsystems & nanoengineering · 2025
    Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Austin J TaylorCollege of Electrical and Computer Engineering, University of Georgia, Athens, GA 30602 USA.
Trent SlutzkyClarke Central High School, Athens, GA 30605 USA.
Leah FeuermanDepartment of Physics, Occidental College, Los Angeles, CA 90041 USA.
Hongliang RenDepartment of Biomedical Engineering, National University of Singapore, Singapore 119077.
Junichi TokudaDepartment of Radiology, Brigham and Women's Hospital, Boston MA 02115 USA.
Kent NilssonDepartment of Cardiology, Piedmont Athens Regional, Athens, GA 30606.
Zion Tsz Ho TseCollege of Electrical and Computer Engineering, University of Georgia, Athens, GA 30602 USA.

Funding

Atlanta Clinical and Translational Science Institute (ACTSI) RenewalUL1TR000454 · NCATS · EMORY UNIVERSITY · PI STEPHENS, DAVID S · 2012 to 2016
$25.8M
NCATS NIH HHS UL1 TR000454
6 · The paper itself

Abstract

Foldable origami structures have been implemented into robotics as a way of compacting joints and circuitry into smaller structures. This technique is especially useful in minimally invasive surgical instruments, where the goal is to create slimline devices that can be inserted through small incisions. Origami also has the potential to cut costs by reducing the amount of material required for assembly. Origami devices are especially suitable for MRI-guided procedures, where instruments must be nonmagnetic because origami is more suitable for flexible, non-metallic materials. MR conditional surgical instruments enable intraoperative MRI procedures that provide superior imaging capabilities to physicians to allow for safer procedures. This work presents an MR conditional joint developed using origami techniques that reduces costs by eliminating assembly of various components and has potential applications in endoscopy. The joint is a compliant rolling-contact element that employs curved-folding origami techniques. A chain of these joints can be constructed from a single sheet of material, eliminating assembly of numerous materials to produce a final product, which is specifically advantageous for constructing low-cost, disposable surgical devices. The prototype contains a degree of bending of ±9 degrees per joint, a response time of less than 4 seconds and an actuation force of 0.5 N using a 1.25 A current. The MRI results showed a minimal artifact of less than 1 mm measured from the boundary of the joint chain and a SNR reduction of less than 10%.