ArticleCancer reports (Hoboken, N.J.)2020
Evaluation of the clinical utility of maximum intensity projections of 3D contrast-enhanced, T1-weighted imaging for the detection of brain metastases.
Article in Cancer reports (Hoboken, N.J.), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- The sensitivity of MIPs of 3D contrast-enhanced VIBE T1-weighted imaging for the detection of small brain metastases (≤ 5 mm) on 1.5 tesla MRI.The neuroradiology journal · 2024Article
- Evaluation of the clinical utility of maximum intensity projections of 3D contrast-enhanced, T1-weighted imaging for the detection of brain metastases.Cancer reports (Hoboken, N.J.) · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundTo visualize and assess brain metastases on magnetic resonance imaging, radiologists face an ever-increasing pressure to perform faster and more efficiently. The usage of maximum intensity projections (MIPs) of contrast-enhanced T1-weighed (T1ce) magnetization-prepared rapid acquisition with gradient echo (MP-RAGE) images proposes to increase reading efficiency by increasing lesion conspicuity while reducing in the number of images to be reviewed.
aimTo assess if MIPs save reading time and achieve the same level of diagnostic accuracy as standard 1 mm T1ce images for the detection of brain metastases.
methodsForty-four patients were included in this retrospective study. Axial reformations of T1ce MP-RAGE (TR/TE = 2300/2.25 ms, resolution = 1 mm
resultsAbout 22.5 61.2 s/study and 43.8 ± 159.9 s/study were saved using 5 and 10 mm MIPs, respectively. Combined average sensitivity was 92.0% for 5 mm MIPs and 86.3% for 10 mm MIPs compared to standard 1 mm axial slices, with an average rate of 0.98 and 0.57 false positives per study, respectively
conclusionWhile 5 mm and 10 mm T1ce MP-RAGE MIPs showed a clinical benefit in reducing reading times for evaluation of brain metastases, they should be used in conjunction with standard 1 mm images for best sensitivity and specificity, a practice which possibly annuls their benefit.