Evidence map›Paper›PMID 32768620›Full record

ArticleIndian pacing and electrophysiology journal

Contact-force monitoring increases accuracy of right ventricular voltage mapping avoiding "false scar" detection in patients with no evidence of structural heart disease.

Luigi Sciarra, Zefferino Palamà, Martina Nesti, Chiara Lanzillo, Mauro Di Roma, Ermenegildo De Ruvo, Antonio Gianluca Robles, Elena Cavarretta, Antonio Scarà, Lucia De Luca and 6 more

Open access · goldAbstract read
In one paragraph

Article in Indian pacing and electrophysiology journal. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.6field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

16 authors at 5 institutions in 1 country.

Luigi SciarraCardiology Unit, Policlinico Casilino, Rome, Italy.
Zefferino PalamàCardiology Unit, Policlinico Casilino, Rome, Italy; Cardiology Unit, Casa di Cura "Villa Verde", Taranto, Italy. Electronic address: zefferino.palama@icloud.com.
Martina NestiCardiovascular and Neurology Department, Ospedale San Donato, Arezzo, Italy.
Chiara LanzilloCardiology Unit, Policlinico Casilino, Rome, Italy.
Mauro Di RomaRadiology Unit, Policlinico Casilino, Rome, Italy.
Ermenegildo De RuvoCardiology Unit, Policlinico Casilino, Rome, Italy.
Antonio Gianluca RoblesCardiology Unit, Policlinico Casilino, Rome, Italy.
Elena CavarrettaDepartment of Medical-Surgical Sciences and Biotechnologies, Sapienza University of Rome, Latina, Italy; Mediterranea Cardiocentro, Naples, Italy.
Antonio ScaràCardiology Unit, Policlinico Casilino, Rome, Italy.
Lucia De LucaCardiology Unit, Policlinico Casilino, Rome, Italy.
Domenico GriecoCardiology Unit, Policlinico Casilino, Rome, Italy.
Mariano RilloCardiology Unit, Casa di Cura "Villa Verde", Taranto, Italy.
Silvio RomanoCardiology, L'Aquila University, L'Aquila, Italy.
Renata PetroniCardiology, L'Aquila University, L'Aquila, Italy.
Maria PencoCardiology, L'Aquila University, L'Aquila, Italy.
Leonardo CalòCardiology Unit, Policlinico Casilino, Rome, Italy.
Policlinico Casilino · ITUniversity of L'Aquila · ITCasa di Cura Villa Garda · ITClinica Mediterranea · ITOspedale San Donato · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeElectroanatomical mapping (EAM) could increase cardiac magnetic resonance imaging (CMR) sensitivity in detecting ventricular scar. Possible bias may be scar over-estimation due to inadequate tissue contact. Aim of the study is to evaluate contact-force monitoring influence during EAM, in patients with idiopathic right ventricular arrhythmias.

methods20 pts (13 M; 43 ± 12 y) with idiopathic right ventricular outflow tract (RVOT) arrhythmias and no structural abnormalities were submitted to Smarttouch catheter Carto3 EAM. Native maps included points collected without considering contact-force. EAM scar was defined as area ≥1 cm

resultsAn EAM was created for each patient (345 ± 85 points). After removing poor contact points, a mean of 149 ± 60 points was collected. The percentage of false scar, collected during contact force blinded mapping compared to total volume, was 6.0 ± 5.2% for bipolar scar and 7.1 ± 5.9% for unipolar scar, respectively. No EAM scar was present after poor contact points removal. Right ventricular areas analysis revealed a greater number of points with contact force < 5 g acquired in free wall, where reduced mean bipolar and unipolar voltage were recorded.

conclusionsTo date this is the first work conducted on structurally normal hearts in which contact-force significantly increases EAM accuracy, avoiding "false scar" related to non-adequate contact between catheter and tissue.

Indexed as

Cardiac magnetic resonanceContact forceRight ventricular mapVentricular scar

Identifiers

PMID32768620
PMCPMC7691776
OpenAlexW3047775903

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.